Abstract

Assessment of inhalable dust exposure requires reliable sampling methods in order to measure airborne inhalable particles' concentrations. Many inhalable aerosol samplers can be used but their performances widely vary and remain unknown in some cases. The sampling performance of inhalable samplers is strongly dependent on particle size and ambient air velocity. Five inhalable aerosol samplers have been studied in two laboratory wind tunnels using polydisperse glass-beads' test aerosol. Samplers tested were IOM sampler (UK), two versions of CIP 10-I sampler, v1 and v2 (F), 37-mm closed face cassette sampler (USA), 37-mm cassette fitted up with an ACCU-CAP insert (USA), and Button sampler (USA). Particle size-dependent sampling efficiencies were measured in a horizontal wind tunnel under a 1 m s(-1) wind velocity and in a vertical tunnel under calm air, using a specific method with Coulter(R) counter particle size number distribution determinations. Compared with CEN-ISO-ACGIH sampling criteria for inhalable dust, the experimental results show fairly high sampling efficiency for the IOM and CIP 10-I v2 samplers and slightly lower efficiencies for the Button and CIP 10-I v1 samplers. The closed face cassette (4-mm orifice) produced the poorest performances of all the tested samplers. This can be improved by using the ACCU-CAP internal capsule, which prevents inner wall losses inside the cassette. Significant differences between moving air and calm air sampling efficiency were observed for all the studied samplers.

摘要

评估可吸入粉尘暴露需要可靠的采样方法,以便测量空气中可吸入颗粒物的浓度。可以使用许多可吸入气溶胶采样器,但它们的性能差异很大,在某些情况下仍不为人知。可吸入采样器的采样性能在很大程度上取决于颗粒大小和环境空气流速。使用多分散玻璃珠测试气溶胶,在两个实验室风洞中对五种可吸入气溶胶采样器进行了研究。测试的采样器有英国的IOM采样器、法国的两种版本的CIP 10-I采样器(v1和v2)、美国的37毫米封闭面盒式采样器、装有ACCU-CAP插入件的37毫米盒式采样器(美国)以及按钮式采样器(美国)。在水平风洞中1 m s(-1)的风速下以及在垂直风洞中平静空气条件下,使用库尔特计数器测定颗粒大小数量分布的特定方法,测量了与颗粒大小相关的采样效率。与CEN-ISO-ACGIH可吸入粉尘采样标准相比,实验结果表明,IOM和CIP 10-I v2采样器的采样效率相当高,而按钮式采样器和CIP 10-I v1采样器的效率略低。封闭面盒式采样器(4毫米孔口)在所有测试采样器中表现最差。使用ACCU-CAP内囊可以改善这种情况,它可以防止盒式采样器内部的内壁损失。对于所有研究的采样器,观察到移动空气和静止空气采样效率之间存在显著差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验