Suppr超能文献

中央角膜厚度对金氏压平眼压计测量选定埃塞俄比亚人群眼内压的影响。

The influence of central corneal thickness on intraocular pressure measured by goldmann applanation tonometry among selected Ethiopian communities.

机构信息

Department of Ophthalmology, Jimma University, Jimma, Ethiopia.

出版信息

J Glaucoma. 2010 Oct-Nov;19(8):514-8. doi: 10.1097/IJG.0b013e3181ca7708.

Abstract

BACKGROUND

Estimates of intraocular pressure (IOP) are influenced directly by the central corneal thickness (CCT). We assume and apply a single value for CCT (520 μm) in applanation tonometry estimates, although there is compelling evidence that CCT varies between individuals.

OBJECTIVE

To determine the influence of CCT and other factors on IOP among Ethiopians.

METHODS

A cross sectional study was conducted among 300 sampled individuals from June to July 2006. The CCT was measured using OcuScan® R×P Ophthalmic Ultrasound and readings of IOP were made with Goldmann applanation tonometer. The data was analyzed using SPSS version 12 and S-Plus 2000 of statistical packages.

RESULTS

Out of 300 individuals, 184 (61.3%) were males. The mean age was 42.57 years (SD±16.71), mean IOP 13.39 mm Hg (SD±2.81), and mean CCT 518.68 μm (SD±32.92). There was statistically significant relationship between CCT and IOP (r=0.199, P<0.001) and a borderline statistically significant detectable change of CCT with age (r=0.012, P=0.057) with a downward trend of at least 0.001 mm decrease in CCT/decade starting from age 30 years but with pronounced change from 50 years onward. For every 30 μm difference in CCT from the mean in either way, there was an approximately 1.1 mm Hg difference in the estimated IOP from the mean IOP (13.40 mm Hg). No significant relationship was found between IOP and age, sex or ethnicity (P>0.05).

CONCLUSION

The CCT of Ethiopians is thin and hence can result in underestimation of IOP measured by GAT.

摘要

背景

眼压(IOP)的估计值直接受中央角膜厚度(CCT)的影响。我们假设并应用平面眼压计估计值中的单个 CCT 值(520μm),尽管有令人信服的证据表明 CCT 在个体之间存在差异。

目的

确定 CCT 和其他因素对埃塞俄比亚人 IOP 的影响。

方法

2006 年 6 月至 7 月期间对 300 名抽样个体进行了横断面研究。使用 OcuScan®R×P 眼科超声测量 CCT,使用 Goldmann 压平眼压计测量 IOP。使用 SPSS 版本 12 和 S-Plus 2000 统计软件包分析数据。

结果

在 300 名个体中,184 名(61.3%)为男性。平均年龄为 42.57 岁(标准差±16.71),平均 IOP 为 13.39mmHg(标准差±2.81),平均 CCT 为 518.68μm(标准差±32.92)。CCT 与 IOP 之间存在统计学显著关系(r=0.199,P<0.001),CCT 与年龄之间存在边界统计学显著可检测变化(r=0.012,P=0.057),自 30 岁起 CCT 以至少 0.001mm/十年的趋势下降,但自 50 岁起变化明显。CCT 每偏离平均值 30μm,估计的 IOP 与平均值相差约 1.1mmHg(13.40mmHg)。IOP 与年龄、性别或种族之间无显著关系(P>0.05)。

结论

埃塞俄比亚人的 CCT 较薄,因此可能导致 GAT 测量的 IOP 低估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验