Suppr超能文献

眼压升高的眼中的 Goldmann 压平眼压测量和动态轮廓眼压测量:IOP 随后经医学正常化后在同一眼中的比较。

Goldmann applanation tonometry and dynamic contour tonometry in eyes with elevated intraocular pressure (IOP): comparison in the same eyes after subsequent medical normalization of IOP.

机构信息

Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2010 Nov;248(11):1611-6. doi: 10.1007/s00417-010-1462-2. Epub 2010 Jul 22.

Abstract

BACKGROUND

Although it is widely accepted that the Pascal dynamic contour tonometry (DCT) reading is higher than Goldmann applanation tonometry (GAT) in normal range of intraocular pressure (IOP), it remains unclear whether DCT reading is higher or lower than GAT in an eye with severely elevated IOP. This study aimed to compare the IOP measurements obtained using GAT with DCT in eyes with elevated IOP and to compare the GAT and DCT measurements in the same eyes after subsequent normalization of the IOP with medical therapy.

METHODS

Eyes with IOP greater than 30 mmHg as measured by GAT at the initial examination were enrolled for a prospective study. IOP was measured by GAT and DCT. Central corneal thickness (CCT) was measured using a specular microscope. When the GAT-IOP was reduced to below 21 mmHg with medical therapy, DCT and CCT measurements were taken in the same eyes.

RESULTS

Measurements from 27 patients were suitable for statistical analysis. At baseline examination, the mean DCT was significantly lower than their mean GAT (30.0 ± 5.8 mmHg vs 38.7 ± 9.1 mmHg, P < 0.001). After the IOP-lowering medical therapy had been instituted, the mean DCT was significantly higher than the mean GAT (17.9 ± 3.1 mmHg vs 15.6 ± 2.7 mmHg, P < 0.001). The mean post-treatment IOP reduction was 12.1 mmHg (40.3%) by DCT and 23.1 mmHg (59.7%) by GAT. The mean CCT showed no significant difference after the IOP-lowering therapy (537.7 ± 31.4 μm vs 543.1 ± 47.7 μm, P = 0.596). The mean ocular pulse amplitude decreased significantly after the medical treatment (3.16 ± 1.24 mmHg vs 2.07 ± 0.93 mmHg, P < 0.001).

CONCLUSION

DCT-IOP, which is higher than GAT-IOP in normotensive eyes, is lower in eyes with GAT-IOP exceeding 30 mmHg.

摘要

背景

虽然人们普遍认为帕斯卡动态轮廓眼压计(DCT)读数在正常眼压范围内高于压平眼压计(GAT),但在眼压严重升高的眼中,DCT 读数是高于还是低于 GAT 尚不清楚。本研究旨在比较眼压升高的眼中使用 GAT 和 DCT 测量的眼压,并比较使用药物治疗使眼压正常化后同一眼中的 GAT 和 DCT 测量值。

方法

初始检查时 GAT 测量的眼压大于 30mmHg 的眼被纳入前瞻性研究。使用 GAT 和 DCT 测量眼压。使用共焦显微镜测量中央角膜厚度(CCT)。当 GAT 眼压降至 21mmHg 以下时,在同一眼中进行 DCT 和 CCT 测量。

结果

27 例患者的测量值适合进行统计学分析。在基线检查时,DCT 的平均读数明显低于 GAT(30.0±5.8mmHg 比 38.7±9.1mmHg,P<0.001)。在开始降低眼压的药物治疗后,DCT 的平均读数明显高于 GAT(17.9±3.1mmHg 比 15.6±2.7mmHg,P<0.001)。DCT 眼压降低 12.1mmHg(40.3%),GAT 眼压降低 23.1mmHg(59.7%)。眼压降低治疗后 CCT 平均值无明显差异(537.7±31.4μm 比 543.1±47.7μm,P=0.596)。治疗后,眼脉冲幅度明显下降(3.16±1.24mmHg 比 2.07±0.93mmHg,P<0.001)。

结论

在正常眼压的眼中,DCT-IOP 高于 GAT-IOP,而在 GAT-IOP 超过 30mmHg 的眼中,DCT-IOP 较低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验