Suppr超能文献

植入衍射型多焦点人工晶状体后的光学分析、阅读性能和生活质量评估。

Optical analysis, reading performance, and quality-of-life evaluation after implantation of a diffractive multifocal intraocular lens.

机构信息

Department of Refractive Surgery, Vissum Corporation-Instituto Oftalmológico de Alicante, Alicante, Spain.

出版信息

J Cataract Refract Surg. 2011 Jan;37(1):27-37. doi: 10.1016/j.jcrs.2010.07.035.

Abstract

PURPOSE

To evaluate the reading performance, changes in quality of life, and optical performance after cataract surgery with multifocal diffractive intraocular lens (IOL) implantation.

SETTING

Vissum Corporation, Alicante, Spain.

DESIGN

Prospective case series.

METHODS

Patients with bilateral cataract had implantation of Acri.LISA 366D multifocal IOLs. Visual acuity and contrast sensitivity outcomes were evaluated during a 6-month follow-up. Other parameters evaluated included reading performance (Salzburg Reading Desk), a 25-item quality-of-life questionnaire (National Eye Institute Visual Functioning Questionnaire-25 [NEI VFQ-25] and appendix NEI VFQ-39), and ocular optical performance (ocular aberrometry and modulation transfer function).

RESULTS

The study included 48 eyes (24 patients) ranging in age from 47 to 77 years. The mean uncorrected distance visual acuity (logMAR) improved significantly 1 month postoperatively (P<.01), with no significant changes afterward (6 months, P≥.06). The mean reading acuity without correction improved significantly from 0.68 logRAD ± 0.20 (SD) to 0.16 ± 0.08 logRAD 1 month after surgery (P < .01). However, it was worse by the end of the follow-up (6 months, P = .04). During the follow-up, no significant changes were found in the mean reading speed without near correction (6 months, P = .50). Contrast sensitivity improved significantly at all spatial frequencies under photopic and scotopic conditions after surgery (6 months, P≤.02). The quality-of-life index related to reading ability also improved significantly (3 months, P = .03).

CONCLUSION

Implantation of the multifocal diffractive IOL significantly improved reading performance, which had a positive effect on the patient's quality of life postoperatively.

FINANCIAL DISCLOSURE

No author has a financial or proprietary interest in any material or method mentioned.

摘要

目的

评估白内障术后使用多焦点衍射型人工晶状体(IOL)植入的阅读性能、生活质量变化和光学性能。

设置

Vissum 公司,阿利坎特,西班牙。

设计

前瞻性病例系列。

方法

双眼白内障患者植入 Acri.LISA 366D 多焦点 IOL。在 6 个月的随访期间评估视力和对比敏感度结果。评估的其他参数包括阅读性能(萨尔茨堡阅读台)、25 项生活质量问卷(国家眼科研究所视觉功能问卷-25 [NEI VFQ-25]和附录 NEI VFQ-39)和眼部光学性能(眼像差和调制传递函数)。

结果

该研究共纳入 48 只眼(24 例),年龄 47 至 77 岁。术后 1 个月未矫正远视力(logMAR)显著改善(P<.01),之后无显著变化(6 个月,P≥.06)。术后 1 个月,未经矫正的平均阅读视力从 0.68 logRAD ± 0.20(SD)显著提高至 0.16 ± 0.08 logRAD(P <.01)。然而,在随访结束时(6 个月,P =.04)情况更差。在随访期间,未经近矫正的平均阅读速度无明显变化(6 个月,P =.50)。在明、暗适应条件下,所有空间频率的对比敏感度均显著提高(6 个月,P≤.02)。与阅读能力相关的生活质量指数也显著提高(3 个月,P =.03)。

结论

多焦点衍射型 IOL 的植入显著改善了阅读性能,对术后患者的生活质量有积极影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验