Suppr超能文献

利用 Schwalbe 线作为标志,通过高清光学相干断层扫描进行新型前房角测量。

Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark.

机构信息

Singapore Eye Research, Institute and Singapore National Eye Centre, Singapore.

出版信息

Br J Ophthalmol. 2011 Jul;95(7):955-9. doi: 10.1136/bjo.2010.189217. Epub 2010 Dec 22.

Abstract

OBJECTIVE

To propose the Schwalbe line (SL) as a new anatomical landmark, independent of the scleral spur (SS) location, for assessing anterior chamber angle (ACA) width quantitatively with high-definition optical coherence tomography (HD-OCT).

METHODS

Study subjects underwent dark-room gonioscopy and HD-OCT in one randomly selected eye. The authors developed a computer-aided program to define two new quantitative parameters for assessing ACA width: Schwalbe line-angle opening distance (SL-AOD) measured at the SL, and Schwalbe line-trabecular-iris space area (SL-TISA) measured 500 μm from the SL. The associations between SL parameters, SS parameters and gonioscopic grading were evaluated.

RESULTS

Seventy-three (47 females, 26 males) subjects were recruited, the majority of whom were Chinese (89%). The authors excluded 29 images (19.9%) owing to poor image quality, leaving 117 HD-OCT images (65 nasal, 52 temporal) for analysis. SL and SS could be identified in 95% and 85% of quadrants respectively (p = 0.035). SL-AOD and SL-TISA were significantly correlated with SS parameters (all r ≥ 0.85) and gonioscopic grading (all r ≥ 0.69). In eyes with closed angles (n = 36), SL parameters showed strong correlations with gonioscopic grading (r ranged from 0.43 to 0.44). Conclusions Novel angle parameters, based on SL as a landmark, may be useful to quantify ACA width and to assess for risk of angle closure.

摘要

目的

提出 Schwalbe 线(SL)作为一个新的解剖学标志,独立于巩膜突(SS)位置,用于使用高清光学相干断层扫描(HD-OCT)定量评估前房角(ACA)宽度。

方法

研究对象在一只随机选择的眼中接受暗室房角镜检查和 HD-OCT 检查。作者开发了一种计算机辅助程序,用于定义两个用于评估 ACA 宽度的新定量参数:在 SL 处测量的 Schwalbe 线-房角开口距离(SL-AOD),以及距 SL 500μm 处测量的 Schwalbe 线-小梁-虹膜空间面积(SL-TISA)。评估了 SL 参数、SS 参数和房角镜分级之间的相关性。

结果

共招募了 73 名(47 名女性,26 名男性)受试者,其中大多数为中国人(89%)。由于图像质量差,作者排除了 29 张图像(19.9%),留下 117 张 HD-OCT 图像(65 个鼻侧,52 个颞侧)进行分析。SL 和 SS 分别可在 95%和 85%的象限中识别(p=0.035)。SL-AOD 和 SL-TISA 与 SS 参数(所有 r≥0.85)和房角镜分级(所有 r≥0.69)均显著相关。在闭角眼(n=36)中,SL 参数与房角镜分级具有很强的相关性(r 范围为 0.43 至 0.44)。结论:基于 SL 作为标志的新角度参数可能有助于定量评估 ACA 宽度和评估闭角风险。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验