Ultrasound Med Biol. 2011 Mar;37(3):376-85. doi: 10.1016/j.ultrasmedbio.2010.11.018. Epub 2011 Jan 21.
Three-dimensional (3-D) power Doppler angiography (3-D-PDA) allows visualisation of Doppler signals within the placenta and their quantification is possible by the generation of vascular indices by the 4-D View software programme. This study aimed to investigate intra- and interobserver reproducibility of 3-D-PDA analysis of stored datasets at varying gestations with the ultimate goal being to develop a tool for predicting placental dysfunction. Women with an uncomplicated, viable singleton pregnancy were scanned at 12, 16 or 20 weeks gestational age groups. 3-D-PDA datasets acquired of the whole placenta were analysed using the VOCAL software processing tool. Each volume was analysed by three observers twice in the A plane. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICCs) and Bland Altman plots. At each gestational age group, 20 low risk women were scanned resulting in 60 datasets in total. The ICC demonstrated a high level of measurement reliability at each gestation with intraobserver values >0.90 and interobserver values of >0.6 for the vascular indices. Bland Altman plots also showed high levels of agreement. Systematic bias was seen at 20 weeks in the vascular indices obtained by different observers. This study demonstrates that 3-D-PDA data can be measured reliably by different observers from stored datasets up to 18 weeks gestation. Measurements become less reliable as gestation advances with bias between observers evident at 20 weeks.
三维(3-D)能量多普勒血管造影(3-D-PDA)可用于观察胎盘内的多普勒信号,并通过 4-D View 软件程序生成血管指数来实现其量化。本研究旨在调查在不同妊娠阶段存储数据集的 3-D-PDA 分析的观察者内和观察者间可重复性,最终目标是开发一种预测胎盘功能障碍的工具。对 12、16 或 20 孕周的正常、单胎妊娠女性进行扫描。使用 VOCAL 软件处理工具对整个胎盘的 3-D-PDA 数据集进行分析。每个体积均在 A 平面由三位观察者进行两次分析。通过组内相关系数(ICC)和 Bland-Altman 图评估观察者内和观察者间的可靠性。在每个妊娠年龄组中,对 20 名低危女性进行扫描,总共获得 60 个数据集。ICC 表明,在每个妊娠阶段,血管指数的观察者内值>0.90,观察者间值>0.6,测量具有高度可靠性。Bland-Altman 图也显示了高度的一致性。不同观察者获得的血管指数在 20 周时存在系统偏差。本研究表明,不同观察者可以从存储的数据集可靠地测量 3-D-PDA 数据,直到妊娠 18 周。随着妊娠的进展,测量的可靠性降低,观察者之间存在偏差,这在 20 周时很明显。