University of Washington, Department of Bioengineering, Seattle, Washington 98195, USA.
J Biomed Opt. 2011 Feb;16(2):026015. doi: 10.1117/1.3541792.
The influence of different tissue preservation (a test solution under development and a standard storage solution) on human cornea morphology, refractive index and hydration was assessed noninvasively by ultrahigh-resolution optical coherence tomography (OCT) over time. For 28 days' or 15 days' storage in the preservation media, corneas in the two media exhibited different structural changes with different onset times including epithelial desquamation, edema-induced cornea thickening and change in tissue refractive index. It was found that the variation of the group refractive index over time was only about 2%, while 25% variation of hydration was observed in the storage and subsequent return to normothermic conditions in both preservation media. The results suggest the two media involved different but correlated preservation mechanisms. This study demonstrates that the noncontact, noninvasive, and high-resolution OCT is a powerful tool for noninvasive characterization of tissue morphological changes and hydration process and for assessment of the effects of preservation media on stored tissue integrity. © 2011 Society of Photo-Optical Instrumentation Engineers.
通过超分辨率光学相干断层扫描(OCT),非侵入性地评估了不同组织保存液(一种正在开发的测试溶液和一种标准储存溶液)对人眼角膜形态、折射率和水化程度的影响。在保存液中储存 28 天或 15 天,两种保存液中的角膜表现出不同的结构变化,其起始时间也不同,包括上皮细胞脱落、水肿引起的角膜增厚和组织折射率变化。结果发现,一段时间后,组折射率的变化仅约为 2%,而在两种保存液中储存并随后恢复到正常温度条件下,水化程度的变化为 25%。结果表明,两种保存液涉及不同但相关的保存机制。本研究表明,非接触、非侵入性和高分辨率 OCT 是一种强大的工具,可用于非侵入性地描述组织形态变化和水合过程,并评估保存液对储存组织完整性的影响。 © 2011 美国光电子学学会。