Suppr超能文献

膝关节骨关节炎的放射学关节间隙宽度的变化反应性和测量可靠性:系统评价。

Responsiveness to change and reliability of measurement of radiographic joint space width in osteoarthritis of the knee: a systematic review.

机构信息

Department of Orthopedic Surgery, Brigham and Women's Hospital, Boston, MA, USA.

出版信息

Osteoarthritis Cartilage. 2011 May;19(5):550-6. doi: 10.1016/j.joca.2011.01.023. Epub 2011 Mar 23.

Abstract

OBJECTIVE

The goal of this systematic review was to report the responsiveness to change and reliability of conventional radiographic joint space width (JSW) measurement.

METHOD

We searched the PubMed and Embase databases using the following search criteria: [osteoarthritis (OA) (MeSH)] AND (knee) AND (X-ray OR radiography OR diagnostic imaging OR radiology OR disease progression) AND (joint space OR JSW or disease progression). We assessed responsiveness by calculating the standardized response mean (SRM). We assessed reliability using intra- and inter-reader intra-class correlation (ICC) and coefficient of variation (CV). Random-effects models were used to pool results from multiple studies. Results were stratified by study duration, design, techniques of obtaining radiographs, and measurement method.

RESULTS

We identified 998 articles using the search terms. Of these, 32 articles (43 estimates) reported data on responsiveness of JSW measurement and 24 (50 estimates) articles reported data on measures of reliability. The overall pooled SRM was 0.33 [95% confidence interval (CI): 0.26, 0.41]. Responsiveness of change in JSW measurement was improved substantially in studies of greater than 2 years duration (0.57). Further stratifying this result in studies of greater than 2 years duration, radiographs obtained with the knee in a flexed position yielded an SRM of 0.71. Pooled intra-reader ICC was estimated at 0.97 (95% CI: 0.92, 1.00) and the intra-reader CV estimated at 3.0 (95% CI: 2.0, 4.0). Pooled inter-reader ICC was estimated at 0.93 (95% CI: 0.86, 0.99) and the inter-reader CV estimated at 3.4% (95% CI: 1.3%, 5.5%).

CONCLUSIONS

Measurement of JSW obtained from radiographs in persons with knee is reliable. These data will be useful to clinicians who are planning RCTs where the change in minimum JSW is the outcome of interest.

摘要

目的

本系统评价旨在报告常规放射关节间隙宽度(JSW)测量的变化反应性和可靠性。

方法

我们使用以下搜索标准在 PubMed 和 Embase 数据库中进行搜索:[骨关节炎(OA)(MeSH)] AND(膝关节)AND(X 射线或放射照相术或诊断成像或放射学或疾病进展)AND(关节间隙或 JSW 或疾病进展)。我们通过计算标准化反应均值(SRM)来评估反应能力。我们使用内部和内部读者内部类相关(ICC)和变异系数(CV)来评估可靠性。使用随机效应模型对来自多个研究的结果进行汇总。结果根据研究持续时间、设计、获得射线照片的技术和测量方法进行分层。

结果

我们使用搜索词共确定了 998 篇文章。其中,32 篇文章(43 个估计值)报告了 JSW 测量变化反应能力的数据,24 篇文章(50 个估计值)报告了可靠性测量数据。总体汇总的 SRM 为 0.33 [95%置信区间(CI):0.26,0.41]。JSW 测量变化的反应能力在持续时间超过 2 年的研究中得到了大大改善(0.57)。进一步对持续时间超过 2 年的研究进行分层,膝关节处于弯曲位置获得的射线照片的 SRM 为 0.71。内部读者 ICC 的汇总估计值为 0.97(95%CI:0.92,1.00),内部读者 CV 的估计值为 3.0(95%CI:2.0,4.0)。内部读者 ICC 的汇总估计值为 0.93(95%CI:0.86,0.99),内部读者 CV 的估计值为 3.4%(95%CI:1.3%,5.5%)。

结论

从膝关节射线照片中获得的 JSW 测量值是可靠的。这些数据对于计划以最小 JSW 变化为研究结果的 RCT 的临床医生将非常有用。

相似文献

3
Exercise for hand osteoarthritis.手部骨关节炎的运动疗法
Cochrane Database Syst Rev. 2017 Jan 31;1(1):CD010388. doi: 10.1002/14651858.CD010388.pub2.
8
Stem cell injections for osteoarthritis of the knee.用于膝关节骨关节炎的干细胞注射
Cochrane Database Syst Rev. 2025 Apr 2;4(4):CD013342. doi: 10.1002/14651858.CD013342.pub2.

引用本文的文献

4
Deep learning applications in osteoarthritis imaging.深度学习在骨关节炎成像中的应用。
Skeletal Radiol. 2023 Nov;52(11):2225-2238. doi: 10.1007/s00256-023-04296-6. Epub 2023 Feb 9.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验