Suppr超能文献

使用频域Cirrus HD光学相干断层扫描技术测量视网膜神经纤维层厚度的设备间一致性

Inter-device agreement of retinal nerve fiber layer thickness measurements using spectral domain cirrus HD OCT.

作者信息

Hong Samin, Kim Yeongjun, Shim Jongwoo, Kim Chan Yun, Seong Gong Je

机构信息

Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.

出版信息

Korean J Ophthalmol. 2011 Apr;25(2):105-9. doi: 10.3341/kjo.2011.25.2.105. Epub 2011 Mar 11.

Abstract

PURPOSE

To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects.

METHODS

Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach's alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot.

RESULTS

The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940; ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors.

CONCLUSIONS

The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.

摘要

目的

评估在健康韩国受试者中,使用两台光谱域Cirrus HD光学相干断层扫描(OCT)设备测量视乳头周围视网膜神经纤维层(RNFL)厚度的设备间一致性。

方法

本研究纳入了11名健康志愿者的11只眼睛。使用两台Cirrus HD OCT设备的视盘立方体200×200扫描对视乳头周围RNFL厚度进行计算,对每只眼睛进行扫描。通过Wilcoxon符号秩检验、Friedman检验、Cronbach's α系数(α)、组内相关系数(ICC)、变异系数(COV)和Bland-Altman图,确定两台Cirrus HD OCT在平均、象限和钟点RNFL厚度值方面的设备间一致性。

结果

参与者的平均年龄为25.82±3.28岁,所有参与者的最佳矫正视力最小分辨角对数均为0.00。两台Cirrus HD OCT扫描的信号强度无显著差异(p = 0.317)。平均RNFL厚度的设备间一致性极佳(α,0.940;ICC,0.945;COV,2.45±1.52%)。然而,鼻侧象限RNFL厚度的一致性不太好(α,0.715;ICC,0.716;COV,5.72±4.64%)。此外,在Bland-Atman图上,两台Cirrus HD OCT在RNFL厚度方面的一致性程度根据扫描区域而有所不同。

结论

两台光谱域Cirrus HD OCT设备对视乳头周围RNFL厚度测量的设备间一致性总体上极佳,但根据扫描区域有所不同。因此,医生在判断由不同OCT设备测量的RNFL厚度变化之前应考虑这一事实。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6661/3060386/d6ffc846f520/kjo-25-105-g001.jpg