Diabetes Technol Ther. 2011 Jul;13(7):737-41. doi: 10.1089/dia.2011.0010. Epub 2011 Apr 10.
This study determined the influence of needle length for insulin administration on metabolic control and patient preference in obese patients with diabetes mellitus.
In this multicenter, open-label crossover study, insulin pen needles of two different lengths (5 mm and 8 mm) were compared. A total of 130 insulin-treated type 1 and type 2 diabetes patients with a body mass index ≥30 kg/m(2) were randomized, and 126 patients completed the study. Patients started using the 5-mm needle for 3 months, after which they switched to injecting insulin with the 8-mm needle for another 3 months, or vice versa. Hemoglobin A1c (A1C), fructosamine, and 1,5-anhydroglucitol were measured, and self-reported side effects and patient preference were recorded.
No within-group changes were observed with respect to A1C, serum fructosamine, 1,5-anhydroglucitol, hypoglycemic events, bruising, and pain. When data of all 126 subjects were pooled, there was a small, but significant, difference between needle lengths (5-mm, A1C 7.47 ± 0.9%; 8-mm, 7.59 ± 1.0%; P = 0.02). Patients reported less bleeding with the 5-mm needle (P = 0.04) and less insulin leakage from the skin with the 8-mm needle (P = 0.01). There were no significant differences in patient preference, with 46% of the patients preferring the 5-mm needle, 41% the 8-mm needle, and 13% not preferring a particular needle length.
A 5-mm needle is similar to an 8-mm needle in obese patients with diabetes with respect to metabolic control, injection-related complaints, or patient preference and can be used safely.
本研究旨在探讨胰岛素给药针长度对肥胖糖尿病患者代谢控制和患者偏好的影响。
这是一项多中心、开放标签的交叉研究,比较了两种不同长度(5mm 和 8mm)的胰岛素注射笔用针。共纳入 130 名体质量指数(BMI)≥30kg/m²的 1 型和 2 型糖尿病胰岛素治疗患者,随机分为两组,一组先使用 5mm 针治疗 3 个月,然后换用 8mm 针治疗 3 个月,另一组反之。测量糖化血红蛋白(HbA1c)、果糖胺和 1,5-脱水葡萄糖醇,记录不良反应和患者偏好。
两组患者的 HbA1c、血清果糖胺、1,5-脱水葡萄糖醇、低血糖事件、瘀伤和疼痛均无组内变化。对所有 126 名患者的数据进行汇总分析,两种针长之间存在微小但显著的差异(5mm 组,HbA1c 7.47±0.9%;8mm 组,HbA1c 7.59±1.0%;P=0.02)。与 8mm 针相比,5mm 针患者报告出血更少(P=0.04),8mm 针患者报告皮肤胰岛素漏出更少(P=0.01)。患者偏好差异无统计学意义,46%的患者更喜欢 5mm 针,41%的患者更喜欢 8mm 针,13%的患者不偏爱特定长度的针。
对于肥胖的糖尿病患者,5mm 针与 8mm 针在代谢控制、注射相关不良反应或患者偏好方面相似,且安全可行。