Suppr超能文献

基于 B 样条和正交局部能量的前列腺多模态图像配准

Prostate multimodality image registration based on B-splines and quadrature local energy.

机构信息

Computer Vision and Robotics Group, Universitat de Girona, Girona, Spain.

出版信息

Int J Comput Assist Radiol Surg. 2012 May;7(3):445-54. doi: 10.1007/s11548-011-0635-8. Epub 2011 Jun 26.

Abstract

PURPOSE

Needle biopsy of the prostate is guided by Transrectal Ultrasound (TRUS) imaging. The TRUS images do not provide proper spatial localization of malignant tissues due to the poor sensitivity of TRUS to visualize early malignancy. Magnetic Resonance Imaging (MRI) has been shown to be sensitive for the detection of early stage malignancy, and therefore, a novel 2D deformable registration method that overlays pre-biopsy MRI onto TRUS images has been proposed.

METHOD

The registration method involves B-spline deformations with Normalized Mutual Information (NMI) as the similarity measure computed from the texture images obtained from the amplitude responses of the directional quadrature filter pairs. Registration accuracy of the proposed method is evaluated by computing the Dice Similarity coefficient (DSC) and 95% Hausdorff Distance (HD) values for 20 patients prostate mid-gland slices and Target Registration Error (TRE) for 18 patients only where homologous structures are visible in both the TRUS and transformed MR images.

RESULTS

The proposed method and B-splines using NMI computed from intensities provide average TRE values of 2.64 ± 1.37 and 4.43 ± 2.77 mm respectively. Our method shows statistically significant improvement in TRE when compared with B-spline using NMI computed from intensities with Student's t test p = 0.02. The proposed method shows 1.18 times improvement over thin-plate splines registration with average TRE of 3.11 ± 2.18 mm. The mean DSC and the mean 95% HD values obtained with the proposed method of B-spline with NMI computed from texture are 0.943 ± 0.039 and 4.75 ± 2.40 mm respectively.

CONCLUSIONS

The texture energy computed from the quadrature filter pairs provides better registration accuracy for multimodal images than raw intensities. Low TRE values of the proposed registration method add to the feasibility of it being used during TRUS-guided biopsy.

摘要

目的

前列腺的针吸活检由经直肠超声(TRUS)成像引导。由于 TRUS 对早期恶性肿瘤的可视化敏感性较差,TRUS 图像不能对恶性组织进行适当的空间定位。磁共振成像(MRI)已被证明对早期恶性肿瘤的检测具有敏感性,因此,提出了一种新的二维可变形配准方法,即将活检前 MRI 叠加到 TRUS 图像上。

方法

该配准方法涉及 B 样条变形,归一化互信息(NMI)作为相似性度量,从幅度响应的定向四元滤波器对获得的纹理图像中计算得出。通过计算 20 名患者前列腺中部切片的骰子相似系数(DSC)和 95%hausdorff 距离(HD)值以及仅在 TRUS 和变换后的 MR 图像中可见同源结构的 18 名患者的目标注册误差(TRE),评估所提出方法的配准精度。

结果

该方法和基于强度计算的 NMI 的 B 样条分别提供了平均 TRE 值 2.64±1.37 和 4.43±2.77mm。与基于强度计算的 NMI 的 B 样条相比,我们的方法在 TRE 方面具有统计学上的显著改善,学生 t 检验 p=0.02。与基于强度计算的 NMI 的 B 样条相比,该方法的平均 TRE 提高了 1.18 倍,为 3.11±2.18mm。该方法的平均 DSC 和平均 95%HD 值分别为 0.943±0.039 和 4.75±2.40mm。

结论

从四元滤波器对计算出的纹理能量比原始强度提供了更好的多模态图像配准精度。所提出的配准方法的低 TRE 值增加了其在 TRUS 引导活检中应用的可行性。

文献检索