Optometry and Vision Research, Weinheim, Germany.
Cont Lens Anterior Eye. 2012 Feb;35(1):35-8. doi: 10.1016/j.clae.2011.07.005. Epub 2011 Aug 17.
To (i) analyze the repeatability of fluorescein instillation from a modified fluorescein strip (MFS) compared to a standard fluorescein strip (FS), and to (ii) observe its usefulness in the measurement of the fluorescein break-up time (FBUT) in comparison to the Tearscope (NIBUT).
In-vitro: Intra- and inter-observer repeatability in fluorescein instillation from the MFS and FS was evaluated by fluorescence analysis (n=10, each). In-vivo: BUT of the right eye of 20 randomly selected subjects (mean age 43.3±11.5, range=21-60 years, 8 males, 12 females) was measured by use of the Tearscope and MFS. Subjects were grouped by the Ocular Surface Disease Index (OSDI) score into 8 OSDI+ and 12 OSDI- by a cut-off value of 15.
In-vitro: Intra-observer 95% limit of agreement (LoA) of the MFS was similar to the FS LoA in observer 1 (O1), but better than the FS LoA in observer (O2) (MFS: O1: LoA=±1.98 mW; p=0.179; O2: ±2.71; 0.442; FS: O1: ±1.71; 0.246; O2: ±4.11; 0.512). Inter-observer LoA in fluorescence was better in MFS (±1.42; 0.111) than in FS (±3.71; 0.003). In-vivo: MFS-BUT was significantly shorter than the NIBUT (p=0.002), but significantly correlated (r=0.864, p<0.001). NIBUT and MFS-BUT were significant discriminators (p<0.001) of OSDI±(0.948/8s and 0.938/5s [AUC/cut-off value]; NIBUT and MFS-BUT, respectively).
The MFS was better in the repeatability of fluorescein instillation than the FS. NIBUT and MFS-BUT were good discriminators of dry eye symptoms, but differ in their cut-off values.
(i)分析改良荧光素条(MFS)与标准荧光素条(FS)相比在荧光素滴眼方面的可重复性,并(ii)观察其在测量荧光素泪膜破裂时间(FBUT)方面与泪液干涉仪(NIBUT)相比的有用性。
在体外:通过荧光分析评估 10 名(每位)观察者内和观察者间 MFS 和 FS 荧光素滴眼的可重复性。在体内:使用泪液干涉仪和 MFS 测量 20 名随机选择的受试者(平均年龄 43.3±11.5 岁,范围 21-60 岁,男性 8 名,女性 12 名)右眼的 BUT。根据眼表疾病指数(OSDI)评分,受试者分为 OSDI+组(8 名)和 OSDI-组(12 名),分界值为 15。
在体外:观察者 1(O1)的 MFS 观察者内 95%限差(LoA)与 FS LoA 相似,但优于观察者 2(O2)的 FS LoA(MFS:O1:LoA=±1.98 mW;p=0.179;O2:±2.71;0.442;FS:O1:±1.71;0.246;O2:±4.11;0.512)。荧光内观察者间 LoA 在 MFS 中更好(±1.42;0.111),而在 FS 中更差(±3.71;0.003)。在体内:MFS-BUT 明显短于 NIBUT(p=0.002),但具有显著相关性(r=0.864,p<0.001)。NIBUT 和 MFS-BUT 是 OSDI±(0.948/8s 和 0.938/5s[AUC/截断值])的显著鉴别器(p<0.001)。
MFS 在荧光素滴眼的重复性方面优于 FS。NIBUT 和 MFS-BUT 是干眼症症状的良好鉴别器,但截断值不同。