Suppr超能文献

泪膜破裂自动测量与传统测量方法之间的一致性

Agreement between Automated and Traditional Measures of Tear Film Breakup.

作者信息

Cox Stephanie M, Nichols Kelly K, Nichols Jason J

机构信息

*OD, FAAO †OD, MPH, PhD, FAAO The University of Alabama at Birmingham, School of Optometry, Birmingham, Alabama (all authors).

出版信息

Optom Vis Sci. 2015 Sep;92(9):e257-63. doi: 10.1097/OPX.0000000000000648.

Abstract

PURPOSE

To determine the repeatability and agreement between the noninvasive Keratograph tear break-up time (NIK-BUT) as measured by the Oculus Keratograph 4 and fluorescein tear break-up time (FBUT).

METHODS

Sixty subjects were recruited for two study visits separated by 7 (± 2) days. At each visit, three NIK-BUT measures and FBUT measures were obtained. Each NIK-BUT measure from the Keratograph included a first and an average NIK-BUT. The means of the measures obtained, first NIK-BUT, and average NIK-BUT and FBUT were calculated for each visit. Between- and within-visit agreement was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman 95% limits of agreement (LoA) analyses of log-transformed data.

RESULTS

Between-visit ICCs were 0.53 [95% confidence interval (CI), 0.32 to 0.69] for first NIK-BUT, 0.59 (95% CI, 0.40 to 0.73) for average NIK-BUT, and 0.66 (95% CI, 0.49 to 0.78) for FBUT, whereas 95% LoA were -0.65 to 0.67, -0.44 to 0.48, and -1.14 to 1.10 [back transformed: (visit 1 + 0.01)/(visit 2 + 0.01) = 0.22 to 4.68, 0.36 to 3.02, and 0.07 to 12.59] for the aforementioned methods, respectively. The visit 1 within-visit ICC between first NIK-BUT and FBUT was 0.44 (95% CI, 0.21 to 0.62), whereas the 95% LoA was -0.84 to 1.18 [back transformed: (first NIK-BUT + 0.01)/(FBUT + 0.01) = 0.14 to 15.14]. Likewise, the visit 1 within-visit ICC between average NIK-BUT and FBUT was 0.41 (95% CI, 0.18 to 0.60), whereas the 95% LoA was -0.58 to 1.44 [back transformed: (average NIK-BUT + 0.01)/(FBUT + 0.01) = 0.26 to 27.54].

CONCLUSIONS

The 95% LoA suggest that the average NIK-BUT has better between-visit agreement compared with the first NIK-BUT or FBUT. The first NIK-BUT showed better within-visit agreement with the FBUT than the average NIK-BUT. In addition, there is better between- and within-visit agreement for all measures at lower values.

摘要

目的

确定通过Oculus Keratograph 4测量的无创角膜地形图泪膜破裂时间(NIK-BUT)与荧光素泪膜破裂时间(FBUT)之间的重复性和一致性。

方法

招募60名受试者,进行两次研究访视,间隔7(±2)天。每次访视时,获取三次NIK-BUT测量值和FBUT测量值。角膜地形图的每次NIK-BUT测量值包括首次NIK-BUT和平均NIK-BUT。计算每次访视获得的测量值、首次NIK-BUT、平均NIK-BUT和FBUT的平均值。使用组内相关系数(ICC)和对对数转换数据的Bland-Altman 95%一致性界限(LoA)分析评估访视间和访视内的一致性。

结果

首次NIK-BUT的访视间ICC为0.53 [95%置信区间(CI),0.32至0.69],平均NIK-BUT为0.59(95% CI,0.40至0.73),FBUT为0.66(95% CI,0.49至0.78),而上述方法的95% LoA分别为-0.65至0.67、-0.44至0.48和-1.14至1.10 [反向转换:(访视1 + 0.01)/(访视2 + 0.01)= 0.22至4.68、0.36至3.02和0.07至12.59]。首次NIK-BUT与FBUT的访视1内ICC为0.44(95% CI,0.21至0.62),而95% LoA为-0.84至1.18 [反向转换:(首次NIK-BUT + 0.01)/(FBUT + 0.01)= 0.14至15.14]。同样,平均NIK-BUT与FBUT的访视1内ICC为0.41(95% CI,0.18至0.60),而95% LoA为-0.58至1.44 [反向转换:(平均NIK-BUT + 0.01)/(FBUT + 0.01)= 0.26至27.54]。

结论

95% LoA表明,与首次NIK-BUT或FBUT相比,平均NIK-BUT具有更好的访视间一致性。首次NIK-BUT与FBUT的访视内一致性优于平均NIK-BUT。此外,所有测量值在较低值时访视间和访视内的一致性更好。