Department of Ophthalmology, Armed Forces Capital Hospital, Seongnam, Korea.
Graefes Arch Clin Exp Ophthalmol. 2012 Feb;250(2):247-54. doi: 10.1007/s00417-011-1788-4. Epub 2011 Aug 23.
To evaluate the effect of astigmatism change on measurement of retinal nerve fiber layer (RNFL) and macular thickness by Cirrus HD spectral-domain optical coherence tomography (Cirrus HD OCT; Carl Zeiss Meditec, Dublin, CA, USA).
A total of 30 right eyes from 30 healthy young subjects underwent RNFL and macular thickness measurements using Cirrus HD OCT. Measurements were performed at the baseline state and induced with-the-rule (WTR) and against-the-rule (ATR) astigmatism states by wearing toric soft contact lenses (+1.50 -3.25 diopter × 90° and +1.50 -3.25 diopter × 180° respectively). Differences in RNFL and macular thickness between the baseline state and induced astigmatism states were analyzed.
Wearing toric soft contact lenses induced a mean 2.92 diopter WTR and 3.18 diopter ATR astigmatism respectively. After signal strength change adjustment, RNFL thicknesses of average, superior quadrant, 12 and 6 o'clock hour sectors decreased after induction of a WTR astigmatism (mean difference range, 1.58 to 6.88 μm); RNFL thicknesses of average, nasal, temporal quadrants, 2, 3, and 9 o'clock hour sectors decreased after induction of an ATR astigmatism (mean difference range, 0.75 to 5.11 μm) (all P values <0.05). Macular thickness was not significantly affected by astigmatism changes (all P values ≥ 0.250).
Although the amount of change was not substantial, RNFL thickness measured by Cirrus HD OCT was affected by astigmatism changes induced by contact lenses. It may be warranted to consider the effect of astigmatism on RNFL thickness measured by OCT in eyes with higher degrees of astigmatism.
评估通过 Cirrus HD 频域光学相干断层扫描仪(Cirrus HD OCT;德国卡尔蔡司公司,都柏林,加利福尼亚州,美国)测量散光变化对视网膜神经纤维层(RNFL)和黄斑厚度的影响。
共 30 名健康年轻受试者的 30 只右眼使用 Cirrus HD OCT 进行 RNFL 和黄斑厚度测量。在基线状态和通过佩戴矫正顺规散光(+1.50-3.25 屈光度×90°)和逆规散光(+1.50-3.25 屈光度×180°)的矫正软性接触镜的情况下进行测量。分析了 RNFL 和黄斑厚度在基线状态和诱导性散光状态之间的差异。
佩戴矫正软性接触镜分别诱导出 2.92 屈光度的顺规散光和 3.18 屈光度的逆规散光。在调整信号强度变化后,诱导顺规散光后平均、上象限、12 和 6 点钟区域的 RNFL 厚度减小(平均差异范围,1.58 至 6.88μm);诱导逆规散光后平均、鼻侧、颞侧象限、2、3 和 9 点钟区域的 RNFL 厚度减小(平均差异范围,0.75 至 5.11μm)(所有 P 值均<0.05)。黄斑厚度不受散光变化的显著影响(所有 P 值均≥0.250)。
尽管变化量不大,但 Cirrus HD OCT 测量的 RNFL 厚度受接触镜诱导的散光变化影响。在散光程度较高的眼中,可能需要考虑散光对 OCT 测量的 RNFL 厚度的影响。