Suppr超能文献

与食管体内内镜光学相干断层扫描(OCT)图像相关的运动伪影。

Motion artifacts associated with in vivo endoscopic OCT images of the esophagus.

作者信息

Kang Wei, Wang Hui, Wang Zhao, Jenkins Michael W, Isenberg Gerard A, Chak Amitabh, Rollins Andrew M

机构信息

Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, USA.

出版信息

Opt Express. 2011 Oct 10;19(21):20722-35. doi: 10.1364/OE.19.020722.

Abstract

3-D optical coherence tomography (OCT) has been extensively investigated as a potential screening and/or surveillance tool for Barrett's esophagus (BE). Understanding and correcting motion artifact may improve image interpretation. In this work, the motion trace was analyzed to show the physiological origin (respiration and heart beat) of the artifacts. Results showed that increasing balloon pressure did not sufficiently suppress the physiological motion artifact. An automated registration algorithm was designed to correct such artifacts. The performance of the algorithm was evaluated in images of normal porcine esophagus and demonstrated in images of BE in human patients.

摘要

三维光学相干断层扫描(OCT)已被广泛研究作为巴雷特食管(BE)的潜在筛查和/或监测工具。理解并校正运动伪影可能会改善图像解读。在这项工作中,对运动轨迹进行了分析,以显示伪影的生理来源(呼吸和心跳)。结果表明,增加球囊压力并不能充分抑制生理运动伪影。设计了一种自动配准算法来校正此类伪影。该算法的性能在正常猪食管图像中进行了评估,并在人类患者的BE图像中得到了验证。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5428/3495872/e16f701b866e/oe-19-21-20722-g001.jpg

相似文献

1
Motion artifacts associated with in vivo endoscopic OCT images of the esophagus.
Opt Express. 2011 Oct 10;19(21):20722-35. doi: 10.1364/OE.19.020722.
5
Comprehensive esophageal microscopy by using optical frequency-domain imaging (with video).
Gastrointest Endosc. 2007 May;65(6):898-905. doi: 10.1016/j.gie.2006.08.009. Epub 2007 Mar 26.
10
Endoscopically guided spectral-domain OCT with double-balloon catheters.
Opt Express. 2010 Aug 2;18(16):17364-72. doi: 10.1364/OE.18.017364.

引用本文的文献

2
Learning-based distortion correction enables proximal-scanning endoscopic OCT elastography.
Biomed Opt Express. 2024 Jun 26;15(7):4345-4364. doi: 10.1364/BOE.528522. eCollection 2024 Jul 1.
3
Fetal membrane imaging: current and future perspectives-a review.
Front Physiol. 2024 Jun 27;15:1330702. doi: 10.3389/fphys.2024.1330702. eCollection 2024.
5
Distal planar rotary scanner for endoscopic optical coherence tomography.
Biomed Eng Lett. 2024 Feb 19;14(3):583-592. doi: 10.1007/s13534-024-00353-8. eCollection 2024 May.
6
Numerical method for axial motion artifact correction in retinal spectral-domain optical coherence tomography.
Front Optoelectron. 2020 Dec;13(4):393-401. doi: 10.1007/s12200-019-0951-0. Epub 2019 Dec 15.
7
Optical coherence tomography evaluation of vaginal epithelial thickness during CO laser treatment: A pilot study.
J Biophotonics. 2022 Nov;15(11):e202200052. doi: 10.1002/jbio.202200052. Epub 2022 Aug 11.
8
In Vivo Cellular-Level 3D Imaging of Peripheral Nerves Using a Dual-Focusing Technique for Intra-Neural Interface Implantation.
Adv Sci (Weinh). 2022 Jan;9(3):e2102876. doi: 10.1002/advs.202102876. Epub 2021 Nov 29.
9
Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.
Biomed Opt Express. 2020 Dec 9;12(1):226-246. doi: 10.1364/BOE.409074. eCollection 2021 Jan 1.
10
Balloon catheter-based radiofrequency ablation monitoring in porcine esophagus using optical coherence tomography.
Biomed Opt Express. 2019 Mar 28;10(4):2067-2089. doi: 10.1364/BOE.10.002067. eCollection 2019 Apr 1.

本文引用的文献

2
Endoscopically guided spectral-domain OCT with double-balloon catheters.
Opt Express. 2010 Aug 2;18(16):17364-72. doi: 10.1364/OE.18.017364.
3
Compensation of motion artifacts in catheter-based optical frequency domain imaging.
Opt Express. 2010 May 24;18(11):11418-27. doi: 10.1364/OE.18.011418.
4
Somewhere over the rainbow.
Gastrointest Endosc. 2010 Feb;71(2):354-6. doi: 10.1016/j.gie.2009.09.026.
5
Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine.
Gastrointest Endosc. 2010 Feb;71(2):346-53. doi: 10.1016/j.gie.2009.07.007. Epub 2009 Oct 31.
6
Imaging of subsquamous Barrett's epithelium with ultrahigh-resolution optical coherence tomography: a histologic correlation study.
Gastrointest Endosc. 2010 Feb;71(2):223-30. doi: 10.1016/j.gie.2009.07.005. Epub 2009 Oct 20.
8
Fast rigid registration of vascular structures in IVUS sequences.
IEEE Trans Inf Technol Biomed. 2009 Nov;13(6):1006-11. doi: 10.1109/TITB.2009.2027230. Epub 2009 Jul 28.
9
High-resolution OCT balloon imaging catheter with astigmatism correction.
Opt Lett. 2009 Jul 1;34(13):1943-5. doi: 10.1364/ol.34.001943.
10
Motion artifacts in optical coherence tomography with frequency-domain ranging.
Opt Express. 2004 Jun 28;12(13):2977-98. doi: 10.1364/opex.12.002977.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验