文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

适体-DNA 发夹用于赭曲霉毒素 A 的生物传感。

Aptamer-DNAzyme hairpins for biosensing of Ochratoxin A.

机构信息

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.

出版信息

Biosens Bioelectron. 2012 Feb 15;32(1):208-12. doi: 10.1016/j.bios.2011.12.011. Epub 2011 Dec 13.


DOI:10.1016/j.bios.2011.12.011
PMID:22221796
Abstract

We report an aptasensor for biosensing of Ochratoxin A (OTA) using aptamer-DNAzyme hairpin as biorecognition element. The structure of this engineered nucleic acid includes the horseradish peroxidase (HRP)-mimicking DNAzyme and the OTA specific aptamer sequences. A blocking tail captures a part of these sequences in the stem region of the hairpin. In the presence of OTA, the hairpin is opened due to the formation of the aptamer-analyte complex. As a result, self-assembly of the active HRP-mimicking DNAzyme occurs. The activity of this DNAzyme is linearly correlated with OTA concentration up to 10 nM, showing a limit of detection of 2.5 nM.

摘要

我们报道了一种基于适体-DNA zyme 发夹作为生物识别元件的适体传感器,用于生物传感赭曲霉毒素 A(OTA)。这种工程化核酸的结构包括辣根过氧化物酶(HRP)模拟 DNAzyme 和 OTA 特异性适体序列。一个阻断尾在发夹的茎区捕获这些序列的一部分。在 OTA 的存在下,由于适体-分析物复合物的形成,发夹被打开。结果,具有活性的 HRP 模拟 DNAzyme 发生自组装。该 DNAzyme 的活性与 OTA 浓度呈线性相关,直到 10 nM,检测限为 2.5 nM。

相似文献

[1]
Aptamer-DNAzyme hairpins for biosensing of Ochratoxin A.

Biosens Bioelectron. 2011-12-13

[2]
Rapid high-throughput analysis of ochratoxin A by the self-assembly of DNAzyme-aptamer conjugates in wine.

Talanta. 2013-7-20

[3]
Aptamer-DNAzyme hairpins for amplified biosensing.

Anal Chem. 2009-11-1

[4]
Label-free colorimetric aptasensor for sensitive detection of ochratoxin A utilizing hybridization chain reaction.

Anal Chim Acta. 2014-12-17

[5]
Homogeneous assay of target molecules based on chemiluminescence resonance energy transfer (CRET) using DNAzyme-linked aptamers.

Biosens Bioelectron. 2014-2-13

[6]
Label-free and amplified electrochemical detection of cytokine based on hairpin aptamer and catalytic DNAzyme.

Analyst. 2011-12-23

[7]
An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer.

Biosens Bioelectron. 2010-12-30

[8]
A label-free DNA hairpin biosensor for colorimetric detection of target with suitable functional DNA partners.

Biosens Bioelectron. 2013-5-25

[9]
Exonuclease-assisted multicolor aptasensor for visual detection of ochratoxin A based on G-quadruplex-hemin DNAzyme-mediated etching of gold nanorod.

Mikrochim Acta. 2018-4-21

[10]
Amplified fluorescent aptasensor through catalytic recycling for highly sensitive detection of ochratoxin A.

Biosens Bioelectron. 2014-10-8

引用本文的文献

[1]
Advances in Aptamer-Based Conjugate Recognition Techniques for the Detection of Small Molecules in Food.

Foods. 2024-6-2

[2]
Mg- or Ca-regulated aptamer adsorption on polydopamine-coated magnetic nanoparticles for fluorescence detection of ochratoxin A.

Mikrochim Acta. 2024-2-26

[3]
Aptasensors Based on Non-Enzymatic Peroxidase Mimics: Current Progress and Challenges.

Biosensors (Basel). 2023-12-20

[4]
Design of a Quencher-Free Fluorescent Aptasensor for Ochratoxin A Detection in Red Wine Based on the Guanine-Quenching Ability.

Biosensors (Basel). 2022-5-5

[5]
Sensitive colorimetric detection of ochratoxin A by a dual-functional Au/FeO nanohybrid-based aptasensor.

RSC Adv. 2019-11-25

[6]
A Sensitive Aptasensor Using Biotin-Streptavidin System for Patulin Detection in Apple Juice.

Biosensors (Basel). 2022-1-23

[7]
Recent Advances in Aptamer Sensors.

Sensors (Basel). 2021-2-2

[8]
Recent Progress and Development of G-Quadruplex-Based Luminescent Assays for Ochratoxin A Detection.

Front Chem. 2020-9-1

[9]
Dual flow immunochromatographic assay for rapid and simultaneous quantitative detection of ochratoxin A and zearalenone in corn, wheat, and feed samples.

J Zhejiang Univ Sci B.

[10]
Fluorometric aptamer-based determination of ochratoxin A based on the use of graphene oxide and RNase H-aided amplification.

Mikrochim Acta. 2018-6-30

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索