评估雅培衣原体检测试剂盒在性传播疾病诊所就诊患者中检测沙眼衣原体的效果。

Evaluation of Abbott Testpack Chlamydia for detection of Chlamydia trachomatis in patients attending sexually transmitted diseases clinics.

作者信息

Reichart C A, Gaydos C A, Brady W E, Quinn T C, Hook E W

机构信息

Department of Medicine, Johns Hopkins University School of Medicine, Baltimore City Health Department, Maryland.

出版信息

Sex Transm Dis. 1990 Jul-Sep;17(3):147-51. doi: 10.1097/00007435-199007000-00007.

Abstract

This work compares a rapid solid-phase EIA (Abbott TestPack Chlamydia) to tissue culture and a direct fluorescent antibody test (Syva Microtrak) for detection of C. trachomatis in 436 patients attending two inner-city sexually transmitted diseases (STD) clinics. The prevalence of C. trachomatis by culture was 12% (5% in men, 15% in women). Overall sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TestPack compared to culture were 70%, 98%, 80%, and 96% respectively. In men, 12 specimens were positive by TestPack, while only eight specimens were positive by culture. Six TestPack-positive, culture-negative specimens were further evaluated by centrifugation of culture transport media and examination of the sediment for chlamydia elementary bodies (EBs) using fluorescent monoclonal antibodies to C. trachomatis. Using this procedure, five of six culture negative specimens contained EBs (revised sensitivity 85%, specificity 99%, PPV 92%, NPV 99%). In 285 women evaluable in culture and TestPack, 44 (15%) specimens were culture positive; TestPack was positive in 29 (sensitivity 66%) culture positive women. Of 241 culture negative patients, 238 had negative TestPack results (specificity 99%) and no EBs were detected in the culture-negative, TestPack-positive specimens. Twenty-three (8%) Microtrak specimens were unsatisfactory for testing; two of these were culture and TestPack positive. Therefore, of 263 specimens evaluable using Microtrak, 42 (16%) specimens were culture positive; Microtrak was positive in 32 (sensitivity 76%) culture-positive women. Abbott TestPack Chlamydia is a rapid (25 minute), visually read format requiring no specialized equipment for detection of chalmydia infections with a sensitivity comparable to that of Microtrak.

摘要

本研究比较了快速固相酶免疫测定法(雅培衣原体检测试剂盒)与组织培养法以及直接荧光抗体检测法(赛瓦微迹检测法),以检测436名前往两家市中心性传播疾病(STD)诊所就诊患者的沙眼衣原体。通过培养法检测出的沙眼衣原体患病率为12%(男性为5%,女性为15%)。与培养法相比,检测试剂盒的总体敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)分别为70%、98%、80%和96%。在男性中,检测试剂盒检测出12份标本呈阳性,而培养法仅检测出8份标本呈阳性。对6份检测试剂盒阳性但培养法阴性的标本,通过对培养物运输培养基进行离心,并使用抗沙眼衣原体荧光单克隆抗体检查沉淀物中的衣原体原体(EB),进行进一步评估。采用该方法,6份培养法阴性标本中有5份含有EB(敏感性修正为85%,特异性为99%,PPV为92%,NPV为99%)。在285名可通过培养法和检测试剂盒评估的女性中,44份(15%)标本培养法呈阳性;检测试剂盒在29名(敏感性66%)培养法阳性女性中呈阳性。在241名培养法阴性的患者中,238名检测试剂盒结果为阴性(特异性99%),且在培养法阴性、检测试剂盒阳性的标本中未检测到EB。23份(8%)微迹检测法标本检测结果不理想;其中2份培养法和检测试剂盒均呈阳性。因此,在263份可采用微迹检测法评估的标本中,42份(16%)标本培养法呈阳性;微迹检测法在32名(敏感性76%)培养法阳性女性中呈阳性。雅培衣原体检测试剂盒检测沙眼衣原体感染快速(25分钟),为目视读取形式,无需专门设备,其敏感性与微迹检测法相当。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验