Department of Ophthalmology, Faculty of Medicine, Justus-Liebig-University Giessen, Giessen, Germany.
Invest Ophthalmol Vis Sci. 2012 Aug 17;53(9):5641-52. doi: 10.1167/iovs.12-9974.
The aim of the study was to objectively characterize the function of rods, cones, and intrinsic photosensitive retinal ganglion cells (ipRGCs) in patients with RPE65 mutations by using two published protocols for chromatic pupillometry, and to correlate the data with the clinical phenotype.
The study group comprised 11 patients with RPE65 mutations, and for control purposes, 32 healthy probands and 2 achromats. A custom-made binocular chromatic pupillometer (Bino I) connected to a ColorDome Ganzfeld stimulator was used to assess changes in pupil diameter in response to red (640 nm) and blue (462 nm) light stimuli. Light intensities, stimulus duration, and background varied depending on the protocol used. Results were compared to the clinical phenotype, that is, visual field (Goldmann perimetry), best corrected visual acuity, and full-field stimulus testing (FST).
No significant differences in any of the pupil response parameters were observed in intraday or intervisit variability tests. Pupil responses to rod-weighted stimulation were significantly diminished in all RPE65 patients. Pupil responses to cone-weighted stimuli differed among RPE65 patients and did not always correlate with residual visual field and cone sensitivity loss in FST. Pupil responses to ipRGC-weighted answers were slightly but significantly diminished, and the postillumination pupil response was significantly increased.
Chromatic pupillometry represents a highly sensitive and objective test to quantify the function of rods, cones, and ipRGCs in patients with RPE65 mutations.
本研究的目的是通过使用两种已发表的色觉瞳孔测量协议,客观地描述 RPE65 突变患者的视杆细胞、视锥细胞和内在光敏感视网膜神经节细胞(ipRGC)的功能,并将数据与临床表型相关联。
研究组包括 11 名 RPE65 突变患者,为了控制目的,还包括 32 名健康对照者和 2 名色觉正常者。使用连接至 ColorDome Ganzfeld 刺激器的定制双目色觉瞳孔计(Bino I)来评估瞳孔直径对红光(640nm)和蓝光(462nm)刺激的反应变化。光强度、刺激持续时间和背景根据使用的协议而变化。结果与临床表型(Goldmann 视野计)、最佳矫正视力和全视野刺激测试(FST)进行比较。
在日内或访视间变异性测试中,任何瞳孔反应参数均无显著差异。所有 RPE65 患者的视杆细胞加权刺激的瞳孔反应均显著降低。RPE65 患者的视锥细胞加权刺激的瞳孔反应存在差异,且并不总是与 FST 中的残余视野和视锥细胞敏感性损失相关。ipRGC 加权反应的瞳孔反应略有但显著降低,后光照反应显著增加。
色觉瞳孔测量法是一种高度敏感和客观的测试方法,可定量评估 RPE65 突变患者的视杆细胞、视锥细胞和 ipRGC 功能。