Suppr超能文献

环境温度对脉搏率变异性的影响:作为年轻成年人心率变异性的替代指标

Ambient temperature effect on pulse rate variability as an alternative to heart rate variability in young adult.

作者信息

Shin Hangsik

机构信息

Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea.

出版信息

J Clin Monit Comput. 2016 Dec;30(6):939-948. doi: 10.1007/s10877-015-9798-0. Epub 2015 Oct 28.

Abstract

Pulse rate variability (PRV) is a promising physiological and analytic technique used as a substitute for heart rate variability (HRV). PRV is measured by pulse wave from various devices including mobile and wearable devices but HRV is only measured by an electrocardiogram (ECG). The purpose of this study was to evaluate PRV and HRV at various ambient temperatures and elaborate on the interchangeability of PRV and HRV. Twenty-eight healthy young subjects were enrolled in the experiment. We prepared temperature-controlled rooms and recorded the ECG and photoplethysmography (PPG) under temperature-controlled, constant humidity conditions. The rooms were kept at 17, 25, and 38 °C as low, moderate, and high ambient temperature environments, respectively. HRV and PRV were derived from the synchronized ECG and PPG measures and they were studied in time and frequency domain analysis for PRV/HRV ratio and pulse transit time (PTT). Similarity and differences between HRV and PRV were determined by a statistical analysis. PRV/HRV ratio analysis revealed that there was a significant difference between HRV and PRV for a given ambient temperature; this was with short-term variability measures such as SDNN SDSD or RMSSD, and HF-based variables including HF, LF/HF and normalized HF. In our analysis the absolute value of PTT was not significantly influenced by temperature. Standard deviation of PTT, however, showed significant difference not only between low and moderate temperatures but also between low and high temperatures. Our results suggest that ambient temperature induces a significant difference in PRV compared to HRV and that the difference becomes greater at a higher ambient temperature.

摘要

脉搏率变异性(PRV)是一种很有前景的生理和分析技术,可作为心率变异性(HRV)的替代方法。PRV通过包括移动和可穿戴设备在内的各种设备的脉搏波进行测量,而HRV仅通过心电图(ECG)进行测量。本研究的目的是评估不同环境温度下的PRV和HRV,并阐述PRV和HRV的互换性。28名健康的年轻受试者参与了该实验。我们准备了温度可控的房间,并在温度可控、湿度恒定的条件下记录心电图和光电容积脉搏波描记图(PPG)。这些房间分别保持在17、25和38°C,作为低、中和高环境温度环境。HRV和PRV分别从同步的心电图和PPG测量值中得出,并在时间和频域分析中研究PRV/HRV比值和脉搏传输时间(PTT)。通过统计分析确定HRV和PRV之间的异同。PRV/HRV比值分析显示,在给定的环境温度下,HRV和PRV之间存在显著差异;这在短期变异性测量(如SDNN、SDSD或RMSSD)以及基于高频的变量(包括HF、LF/HF和标准化HF)中表现明显。在我们的分析中,PTT的绝对值不受温度的显著影响。然而,PTT的标准差不仅在低温和中温之间显示出显著差异,在低温和高温之间也显示出显著差异。我们的结果表明,与HRV相比,环境温度会导致PRV出现显著差异,并且在较高的环境温度下这种差异会更大。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/041c/5082608/7418f5ebbc9c/10877_2015_9798_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验