BACKGROUND

This study evaluated 3 potential indicators of gastrointestinal endoscope cleanliness: adenosine triphosphate (ATP), microbiological load, and protein.

METHODS

Before and after cleaning, ATP and microbiological load were determined from swabs of exterior surfaces and rinses of interior suction/accessory channels. Similarly, before and after cleaning, residual protein was determined from rinses of interior suction/accessory channels.

RESULTS

Before cleaning, ATP values were 10,417 relative light units (RLU) from the exterior endoscope surface and 30,281 RLU from the suction/accessory channel rinsates. After cleaning, these ATP values were decreased to 82 RLUs and 104 RLUs, a statistically significant difference. A similar trend was observed with microbiological load, but the change in residual protein from before cleaning to after cleaning was not significant. ATP values reliably reflected microbiological colony counts.

CONCLUSIONS

ATP measurement can provide a reliable, rapid and practical assessment of endoscope cleanliness for routine monitoring in the clinical setting.

摘要

背景

本研究评估了 3 种潜在的胃肠内镜清洁度指标:三磷酸腺苷(ATP)、微生物负荷和蛋白质。

方法

在清洗前后,从外部表面拭子和内部抽吸/附件通道冲洗液中检测 ATP 和微生物负荷。同样,在清洗前后,从内部抽吸/附件通道冲洗液中检测残留蛋白质。

结果

在清洗前,从内镜外表面获得的 ATP 值为 10417 相对光单位(RLU),从抽吸/附件通道冲洗液中获得的 ATP 值为 30281RLU。清洗后,这些 ATP 值分别降低至 82RLU 和 104RLU,差异具有统计学意义。微生物负荷也呈现出类似的趋势,但清洗前后残留蛋白质的变化不显著。ATP 值可靠地反映了微生物菌落计数。

结论

ATP 测量可提供可靠、快速和实用的内镜清洁度评估,适用于临床环境中的常规监测。