The analytical and clinical performance of a new rapid immunochromatography test, the SD Bioline Norovirus test, was evaluated for the detection of human norovirus in fecal specimens. The analytical performance studies were performed for detection limit, reproducibility, cross-reactivity, and interference. For comparison, 92 norovirus-positive stool samples and 126 norovirus-negative samples for which the results were confirmed by 2 different real-time PCR kits were used. The rapid immunochromatography test detected the equivalent of 4.48×10(6) copies/mL of the norovirus genome in stool samples. On performing the repeatability/reproducibility test, samples above this concentration all provided positive results (100%) and 97.8% of the samples slightly below this concentration (2.45×10(6) copies/mL) provided negative results. No cross-reactivity or interference was detected. Positive percent agreement (sensitivity), negative percent agreement (specificity), and overall percent agreement of the rapid immunochromatography test compared with testing by real-time PCR were 90.2%, 100%, and 95.9%, respectively. In addition, the rapid immunochromatography test was completed within 20 min. The SD Bioline Norovirus test was, therefore, easier and more rapid to perform and showed excellent reproducibility, no cross-reactivity, no interference, and high agreement compared with real-time PCR. Thus, this test is useful for rapid screening to identity norovirus infection.

摘要

一种新的快速免疫层析检测试剂盒(SD Bioline Norovirus 检测)用于检测粪便标本中的人类诺如病毒,对其分析和临床性能进行了评估。进行了分析性能研究,包括检测限、重现性、交叉反应性和干扰。为了比较,使用了 92 份诺如病毒阳性粪便样本和 126 份经两种不同实时 PCR 试剂盒确认的诺如病毒阴性样本。快速免疫层析检测法可检测到粪便样本中相当于 4.48×10(6)拷贝/mL 的诺如病毒基因组。在进行重复性/重现性测试时,高于该浓度的所有样本均提供阳性结果(100%),略低于该浓度(2.45×10(6)拷贝/mL)的 97.8%样本则提供阴性结果。未检测到交叉反应或干扰。与实时 PCR 相比,快速免疫层析检测的阳性百分比符合率(敏感性)、阴性百分比符合率(特异性)和总百分比符合率分别为 90.2%、100%和 95.9%。此外,快速免疫层析检测可在 20 分钟内完成。因此,与实时 PCR 相比,SD Bioline Norovirus 检测更易于操作,更快速,具有出色的重现性、无交叉反应、无干扰且与实时 PCR 具有高度一致性。因此,该检测方法对于快速筛查诺如病毒感染非常有用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e46c/7119779/184a63de463c/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验