Techniques used to produce partial spinal cord injuries in animal models have the potential for creating variability in lesions. The amount of tissue affected may influence the functional outcomes assessed in the animals. The recording of somatosensory evoked potentials (SSEPs) may be a valuable tool for assessing the extent of lesion applied in animal models of traumatic spinal cord injury (SCI). Intraoperative tibial SSEP recordings were assessed during surgically induced lateral thoracic hemisection SCI in Sprague-Dawley rats. The transmission of SSEPs, or lack thereof, was determined and compared against the integrity of the dorsal funiculi on each side of the spinal cord upon histological sectioning. An association was found between the presence of an SSEP signal and presence of intact dorsal funiculus tissue. The relative risk is 4.50 (95% confidence interval: 1.83-11.08) for having an intact dorsal funiculus when the ipsilateral SSEP was present compared to when it was absent. Additionally, the amount of spared spinal cord tissue correlates with final functional assessments at nine weeks post injury: BBB (linear regression, R²=0.618, p<0.001) and treadmill test (linear regression, R²=0.369, p=0.016). Therefore, we propose intraoperative SSEP monitoring as a valuable tool to assess extent of lesion and reduce variability between animals in experimental studies of SCI.

摘要

用于在动物模型中产生部分脊髓损伤的技术有可能导致病变的变异性。受影响的组织量可能会影响动物中评估的功能结果。记录体感诱发电位(SSEP)可能是评估外伤性脊髓损伤(SCI)动物模型中应用的病变程度的有价值的工具。在 Sprague-Dawley 大鼠的手术诱导的侧胸半切 SCI 期间评估术中胫骨 SSEP 记录。确定 SSEP 的传输或不存在,并将其与脊髓两侧背柱的完整性进行比较,以进行组织学切片。发现 SSEP 信号的存在与背柱组织完整之间存在关联。当对侧 SSEP 存在时,与不存在时相比,具有完整背柱组织的相对风险为 4.50(95%置信区间:1.83-11.08)。此外,脊髓组织的保留量与伤后 9 周的最终功能评估相关:BBB(线性回归,R²=0.618,p<0.001)和跑步机测试(线性回归,R²=0.369,p=0.016)。因此,我们建议在 SCI 的实验研究中,术中 SSEP 监测作为评估病变程度和减少动物之间变异性的有价值的工具。

相似文献

3
Effect of thoracic spinal cord injury on forelimb somatosensory evoked potential.胸段脊髓损伤对前肢体感诱发电位的影响。
Brain Res Bull. 2021 Aug;173:22-27. doi: 10.1016/j.brainresbull.2021.05.005. Epub 2021 May 12.

引用本文的文献

2
A pig model of symptomatic spinal epidural hematoma.猪症状性脊柱硬膜外血肿模型。
Eur Spine J. 2024 May;33(5):2129-2137. doi: 10.1007/s00586-024-08188-8. Epub 2024 Mar 27.

本文引用的文献

5
Intraoperative electrophysiological monitoring in spine surgery.脊柱手术中的术中电生理监测。
Spine (Phila Pa 1976). 2010 Dec 1;35(25):2167-79. doi: 10.1097/BRS.0b013e3181f6f0d0.
10
Recommendations for the clinical use of somatosensory-evoked potentials.体感诱发电位临床应用建议。
Clin Neurophysiol. 2008 Aug;119(8):1705-1719. doi: 10.1016/j.clinph.2008.03.016. Epub 2008 May 16.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验