Suppr超能文献

青光眼患者中 FDF、FDT、SAP 和扫描激光检眼镜的结构-功能关系。

Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.

机构信息

Department of Ophthalmology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany.

出版信息

Invest Ophthalmol Vis Sci. 2012 Nov 7;53(12):7553-9. doi: 10.1167/iovs.12-10892.

Abstract

PURPOSE

Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma.

METHODS

Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank correlation and linear regression.

RESULTS

Overall, FDF perimetry showed the strongest structure-function relationship (GLOBAL correlation with rim area: 0.44; range of significant sectoral FDF values: 0.23-0.69), followed by FDT (global correlation with rim area: 0.35; range of significant sectoral FDT values: 0.25-0.60). SAP presented with the weakest structure-function relationship and fewer statistically significant results (global correlation with rim volume: 0.32; range of significant sectoral SAP values: 0.23-0.58). Sector-by-sector, the structure-function relationship was greatest in the superotemporal and inferotemporal regions. Weakest correlations were found in the inferonasal and nasal sectors.

CONCLUSIONS

The correlation between structure and function is stronger in FDF and FDT compared with SAP. Correlations are strongest in temporal areas where glaucomatous damage tends to occur first. A better understanding of the structure-function relationship should allow for improved detection and management of glaucoma patients.

摘要

目的

闪光定义式视野检查(FDF)和倍频技术视野检查(FDT)据称比标准自动视野检查(SAP)更早地发现青光眼。本研究旨在探讨青光眼患者的 FDF、FDT、SAP 和共焦激光扫描检眼镜(cSLO)之间的结构-功能关系。

方法

本研究纳入 76 例青光眼患者。患者接受 SAP、Matrix-FDT、FDF 视野检查和 cSLO 检查。使用 Spearman 秩相关和线性回归计算了全局和扇形 cSLO 参数与 SAP、Matrix-FDT 和 FDF 的全局和扇形平均敏感度(MS)之间的结构-功能关系。

结果

总体而言,FDF 视野检查显示出最强的结构-功能关系(与边缘区域的全局相关性:0.44;有意义的扇形 FDF 值范围:0.23-0.69),其次是 FDT(与边缘区域的全局相关性:0.35;有意义的扇形 FDT 值范围:0.25-0.60)。SAP 显示出最弱的结构-功能关系和更少具有统计学意义的结果(与边缘体积的全局相关性:0.32;有意义的扇形 SAP 值范围:0.23-0.58)。按扇形划分,在上方和下方颞区的结构-功能关系最强。在下方鼻侧和鼻侧区域发现的相关性最弱。

结论

与 SAP 相比,FDF 和 FDT 中结构与功能的相关性更强。在青光眼损伤首先发生的颞区,相关性最强。更好地理解结构-功能关系应该可以提高青光眼患者的检测和管理水平。

文献检索