Bureau of Nutritional Sciences, Food Directorate, Health Canada, Canada.
Clin Biochem. 2013 Mar;46(4-5):285-8. doi: 10.1016/j.clinbiochem.2012.11.027. Epub 2012 Dec 5.
There are no direct comparisons of blood glucose values in samples collected with barrier serum tubes (SST) and NaF/potassium oxalate (NaF/KOx) plasma tubes. Collection of samples in SST tubes can offer considerable savings and specimen processing advantages for national level surveys.
Serum and plasma samples were collected under 'field conditions' from a single draw of 3692 individuals participating in the Canadian Health Measures Survey. The samples were analyzed retrospectively using the VITROS GLU Slide method (glucose oxidase-based).
There was a high rate of hemolysis in the NaF/KOx tubes (86.2%) while hemolysis was infrequently observed with the SST tubes (2%). Comparing only blood draws where no hemolysis was observed in both tubes (n=495; paired t-test) showed no effect of tube type on serum/plasma glucose concentrations. This was also observed when data was restricted to cases when only SST samples were not hemolyzed (n=3546; paired t-test).
These data show that both collection tubes can be used under survey collection and processing conditions to measure glucose with our assay system with no difference in reported results.
目前尚无使用屏障血清管(SST)和氟化钠/草酸钾(NaF/KOx)血浆管采集的样本中血糖值的直接比较。在全国性调查中,使用 SST 管采集样本可节省大量成本并具有标本处理优势。
在加拿大健康测量调查中,从 3692 名参与者的单次采血中采集血清和血浆样本。使用 VITROS GLU 幻灯片法(基于葡萄糖氧化酶)对样本进行回顾性分析。
NaF/KOx 管中溶血率很高(86.2%),而 SST 管中溶血很少见(2%)。仅比较在两个管中均未观察到溶血的采血(n=495;配对 t 检验)显示管类型对血清/血浆葡萄糖浓度无影响。当数据仅限于仅 SST 样本未溶血的情况时(n=3546;配对 t 检验)也观察到了这种情况。
这些数据表明,在我们的检测系统中,在调查采集和处理条件下,两种采集管都可用于测量葡萄糖,且报告结果无差异。