Suppr超能文献

中文原发性开角型青光眼患者 Schlemm 管的光谱域光相干断层扫描评估。

Spectral-domain optical coherence tomographic assessment of Schlemm's canal in Chinese subjects with primary open-angle glaucoma.

机构信息

Department of Ophthalmology and Visual Science, Eye, Ear, Nose, and Throat Hospital, School of Shanghai Medicine, Fudan University, Shanghai, China.

出版信息

Ophthalmology. 2013 Apr;120(4):709-15. doi: 10.1016/j.ophtha.2012.10.008. Epub 2013 Jan 23.

Abstract

PURPOSE

To evaluate in vivo features of Schlemm's canal (SC) in patients with primary open-angle glaucoma (POAG) with spectral-domain optical coherence tomography (SD-OCT) and to investigate the relationship of SC size with intraocular pressure (IOP) and glaucoma severity.

DESIGN

Prospective, comparative study.

PARTICIPANTS

Fifty Chinese patients with newly diagnosed POAG who had not undergone surgery and 50 normal Chinese subjects from a population-based, cross-sectional study in Shanghai.

METHODS

All participants underwent SD-OCT. The diameter and area of SC were examined in the temporal and nasal sections and measured with customized software.

MAIN OUTCOME MEASURES

Patient demographics, repeatability and reproducibility assessed with the coefficient of variation (CV) and the intraclass correlation coefficient (ICC), SC parameters and their correlation with IOP, and the mean deviation (MD) of the visual field were analyzed.

RESULTS

The percentage of sections in which SC was observable was similar between eyes with POAG and normal eyes, and ranged from 78% to 86%. For intraobserver repeatability, the CV and ICC values were 7.9% and 0.97 for diameter, and 13.8% and 0.83 for area, respectively. For interobserver repeatability, the CV and ICC values were 13.6% and 0.89 for diameter, and 13.4% and 0.80 for area, respectively. Significant differences between the 2 groups were found for the average SC area (11332 ± 2015 μm(2) vs. 13991 ± 1357 μm(2); P<0.001), but not for the SC diameter (40.2 ± 7.1 μm vs. 45.2 ± 4.0 μm; P = 0.195). In addition, the mean IOP values correlated well only with the SC area (ρ = -0.674, P<0.001), not with the SC diameter (ρ = -0.103, P = 248). No significant correlations were found between the MD values and the SC parameters.

CONCLUSIONS

Eyes with POAG have a decreased SC area compared with normal eyes. A correlation between the SC area and the IOP also was observed. However, the degree of glaucoma damage was not consistently associated with the SC area. Spectral-domain OCT could be used for investigating SC changes in patients with glaucoma.

摘要

目的

利用频域光相干断层扫描(SD-OCT)评估原发性开角型青光眼(POAG)患者 Schlemm 管(SC)的体内特征,并探讨 SC 大小与眼压(IOP)和青光眼严重程度的关系。

设计

前瞻性、对照研究。

参与者

50 名中国新诊断为 POAG 的患者和 50 名来自上海基于人群的横断面研究的正常中国受试者。

方法

所有参与者均接受 SD-OCT 检查。使用定制软件检测颞部和鼻侧节段 SC 的直径和面积。

主要观察指标

患者人口统计学资料,用变异系数(CV)和组内相关系数(ICC)评估重复性和再现性,分析 SC 参数及其与 IOP 的相关性,以及视野平均偏差(MD)。

结果

POAG 眼和正常眼 SC 可观察到的节段百分比相似,范围为 78%至 86%。对于观察者内重复性,直径的 CV 和 ICC 值分别为 7.9%和 0.97,面积的 CV 和 ICC 值分别为 13.8%和 0.83。对于观察者间重复性,直径的 CV 和 ICC 值分别为 13.6%和 0.89,面积的 CV 和 ICC 值分别为 13.4%和 0.80。两组间平均 SC 面积(11332±2015 μm²与 13991±1357 μm²;P<0.001)存在显著差异,但 SC 直径(40.2±7.1 μm与 45.2±4.0 μm;P=0.195)无显著差异。此外,平均 IOP 值仅与 SC 面积(ρ=-0.674,P<0.001)相关,与 SC 直径(ρ=-0.103,P=248)无关。MD 值与 SC 参数之间无显著相关性。

结论

与正常眼相比,POAG 眼的 SC 面积减小。还观察到 SC 面积与 IOP 之间存在相关性。然而,青光眼损害的严重程度与 SC 面积并不一致。频域 OCT 可用于研究青光眼患者的 SC 变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验