活体染料导致晶状体囊硬度增加。

Increase in lens capsule stiffness caused by vital dyes.

机构信息

From the Department of Ophthalmology (Haritoglou, Schumann, Wolf, Kernt) and the Department of Applied Physics and Center for NanoScience (Mauell, Benoit), Ludwig-Maximilians-University, Munich, Germany; the Department of Ophthalmology (Henrich), University Hospital Basel, Basel, Switzerland.

出版信息

J Cataract Refract Surg. 2013 Nov;39(11):1749-52. doi: 10.1016/j.jcrs.2013.02.057. Epub 2013 Sep 4.

Abstract

PURPOSE

To assess potential changes in lens capsule mechanical properties after staining with brilliant blue, indocyanine green (ICG), and trypan blue.

SETTING

Department of Ophthalmology and Applied Physics and Center for NanoScience, Ludwig-Maximilians-University, Munich, Germany.

DESIGN

Experimental study.

METHODS

Fifteen unstained lens capsules were dissected into 7 wedge-shaped parts. Three fragments were stained with brilliant blue 0.025%, ICG 0.05%, and trypan blue 0.06%, respectively, for 1 minute. Another 3 specimens were additionally illuminated using a standard light source. The seventh part served as an untreated control. All specimens were analyzed using atomic force microscopy (AFM) in contact mode with a scan rate of 0.6 Hz. Two scan regions of 10 μm × 10 μm were chosen, and stiffness was determined using AFM in a force spectroscopy mode. The force curves were performed with a data rate of 5000 Hz.

RESULTS

Staining of the samples resulted in an increase in tissue stiffness (brilliant blue: P<.001; ICG: P<.01; trypan blue: P<.05). Additional illumination after staining further increased tissue stiffness, but not significantly. Mean increase in the relative elasticity values were 1.61 ± 0.15 (SD) for brilliant blue, 2.04 ± 0.21 for brilliant blue with illumination, 1.63 ± 0.22 for ICG, 2.01 ± 0.22 for ICG with illumination, 1.23 ± 0.11 for trypan blue, and 1.39 ± 0.11 for trypan blue with illumination. In relation to unstained tissue, the relative elasticity of the stained tissue increased 1.2-fold after illumination.

CONCLUSION

Staining significantly increased the mechanical properties of the human lens capsule.

FINANCIAL DISCLOSURE

No author has a financial or proprietary interest in any material or method mentioned.

摘要

目的

评估经亮蓝、吲哚菁绿(ICG)和台盼蓝染色后晶状体囊机械性能的潜在变化。

设置

德国慕尼黑路德维希-马克西米利安大学眼科和应用物理学系及纳米科学中心。

设计

实验研究。

方法

将 15 个未经染色的晶状体囊分别切成 7 个楔形部分。其中 3 个部分分别用浓度为 0.025%的亮蓝、0.05%的 ICG 和 0.06%的台盼蓝染色 1 分钟,另外 3 个标本用标准光源进行额外照射。第 7 个部分作为未经处理的对照。所有标本均采用原子力显微镜(AFM)在接触模式下以 0.6 Hz 的扫描速率进行分析。选择 2 个 10 μm×10 μm 的扫描区域,采用 AFM 力谱模式测定硬度。力曲线以 5000 Hz 的数据速率进行。

结果

样本染色导致组织硬度增加(亮蓝:P<.001;ICG:P<.01;台盼蓝:P<.05)。染色后额外照射进一步增加了组织硬度,但差异无统计学意义。亮蓝的相对弹性值平均增加 1.61±0.15(SD),亮蓝加光照组为 2.04±0.21,ICG 为 1.63±0.22,ICG 加光照组为 2.01±0.22,台盼蓝为 1.23±0.11,台盼蓝加光照组为 1.39±0.11。与未染色组织相比,染色后组织的相对弹性增加了 1.2 倍。

结论

染色显著增加了人晶状体囊的机械性能。