Department of Ophthalmology, Shimane University Faculty of Medicine, Enya 89-1, Izumo, Shimane, 693-8501, Japan,
Jpn J Ophthalmol. 2014 Jan;58(1):56-61. doi: 10.1007/s10384-013-0280-6. Epub 2013 Oct 8.
To report the reproducibility profile of optic nerve head parameters obtained by computer software-assisted fundus photoplanimetry.
Fundus photographs obtained during a population-based health survey (Sakurae Study) were planimetrically analyzed using newly developed computer software, CDSketch. The parameters assessed included vertical and horizontal cup-to-disc (C/D) ratios, superior and inferior rim-to-disc (R/D) ratios, disc and cup vertical-to-horizontal (V/H) ratios, and disc-macular distance-to-disc diameter (DM/DD) ratio. For intraobserver and interobserver agreement assessments, we calculated the coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) of the mean of three measurements obtained by one observer and a one-time measurement by three observers, respectively.
The intraobserver CVs were between 2.4 % (DM/DD ratio) and 11.0 % (inferior R/D ratio), and the ICCs were between 0.868 (cup V/H ratio) and 0.976 (DM/DD ratio); all intraobserver ICCs had almost perfect agreement (>0.81). The interobserver CVs were between 2.6 % (disc V/H ratio) and 18.0 % (inferior R/D ratio), and the ICCs were between 0.762 (cup V/H ratio) and 0.930 (DM/DD ratio); the interobserver ICCs were categorized as substantial (0.61-0.80) for the inferior R/D and cup V/H ratios and as almost perfect for the other five parameters.
The consistent profiles of the planimetric parameters suggest the suitability of software-assisted photoplanimetry for assessing optic disc characteristics in glaucoma clinical study and practice.
报告使用计算机软件辅助眼底照相视盘平面测量获得的视盘参数的可重复性特征。
使用新开发的计算机软件 CDSketch 对基于人群的健康调查(樱研究)中获得的眼底照片进行平面分析。评估的参数包括垂直和水平杯盘(C/D)比、上和下盘缘到盘(R/D)比、盘和杯的垂直到水平(V/H)比以及盘黄斑距离到盘直径(DM/DD)比。为了评估观察者内和观察者间的一致性,我们分别计算了一位观察者三次测量的平均值的变异系数(CV)和组内相关系数(ICC),以及三位观察者一次测量的 ICC。
观察者内的 CV 为 2.4%(DM/DD 比)至 11.0%(下 R/D 比),ICC 为 0.868(杯 V/H 比)至 0.976(DM/DD 比);所有观察者内的 ICC 均具有高度一致性(>0.81)。观察者间的 CV 为 2.6%(盘 V/H 比)至 18.0%(下 R/D 比),ICC 为 0.762(杯 V/H 比)至 0.930(DM/DD 比);下 R/D 和杯 V/H 比的观察者间 ICC 被归类为中等(0.61-0.80),而其他五个参数的 ICC 则为高度一致。
平面参数的一致特征表明,软件辅助眼底照相在青光眼临床研究和实践中评估视盘特征具有适用性。