Clinic for Orthopaedic and Trauma Surgery, Hospital Bad Cannstatt, Prießnitzweg 24, 70374, Stuttgart, Germany,
Int Orthop. 2014 Apr;38(4):733-9. doi: 10.1007/s00264-013-2157-1. Epub 2013 Oct 27.
The aim of this study was to determine how well pre-operative size selection for total knee and hip arthroplasties based on the digital imaging with and without additional referencing correlated with the size actually implanted.
Size selection planning of total knee arthroplasty by digital templating was documented in 46 cases with reference ball (group A) and in 48 cases without ball (group B). In addition, prospective analysis of pre-operative planning was conducted for 52 acetabular components with reference ball (group C) and 69 without ball (group D) as well as stem planning in 38 cases with ball (group E) and 54 cases without ball (group F). The data were analysed and compared with the size of the final component selected during surgery.
The correlation between planned and implanted size for total knee arthroplasty in group A resulted in femoral anteroposterior (AP) r = 0.8622 and lateral r = 0.8333 and in group B AP r = 0.4552 and lateral r = 0.6950. Tibial in group A was AP r = 0.9030 and lateral r = 0.9074 and in group B AP r = 0.7000 and lateral r = 0.6376. For the acetabular components, the results in group C were r = 0.5998 and group D r = 0.6923. For stems, group E was r = 0.5306 and group F r = 0.5786. No correlation between BMI and the difference between planned and implanted size was found in any of the groups.
In the case of total hip arthroplasty there was a relatively low correlation between planned and implanted sizes with or without reference ball. For total knee arthroplasties the already high precision of size planning was further improved by the additional referencing with a reference ball.
本研究旨在确定基于数字成像(有或无附加参考物)的术前全膝关节和髋关节置换术假体尺寸选择与实际植入尺寸的吻合程度。
通过数字模板对 46 例(A 组)和 48 例(B 组)膝关节置换术进行假体尺寸选择规划,并进行前瞻性分析。此外,对 52 例有参考球(C 组)和 69 例无参考球(D 组)的髋臼组件、38 例有球(E 组)和 54 例无球(F 组)的股骨柄进行术前规划。对数据进行分析,并与手术中最终选择的组件尺寸进行比较。
A 组全膝关节置换术的计划与植入尺寸之间具有较强相关性,股骨前后(AP)r=0.8622,外侧 r=0.8333,B 组 AP r=0.4552,外侧 r=0.6950。A 组胫骨 AP r=0.9030,外侧 r=0.9074,B 组 AP r=0.7000,外侧 r=0.6376。C 组髋臼组件的结果为 r=0.5998,D 组为 r=0.6923。E 组股骨柄的 r=0.5306,F 组为 r=0.5786。在任何一组中,BMI 与计划与植入尺寸之间的差异均无相关性。
在全髋关节置换术中,无论是否有参考球,计划与植入尺寸之间的相关性均较低。对于全膝关节置换术,附加参考球进一步提高了尺寸规划的精度。