European Union legislation has established that plastic food contact materials shall not release primary aromatic amines (PAAs), which are toxic compounds and suspected human carcinogens. As valid alternative to existing methods for PAA determination, which are based on spectrophotometric test or targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) approaches, in this study a LC-Orbitrap-full scan-high resolution mass spectrometry (HRMS) method was devised and validated for the determination of migration levels of 22 PAAs from food contact materials, thus exploiting the specificity of accurate mass measurement. Direct injection of the simulant (acetic acid 3%, w/v) into the LC-MS system after migration, without any pre-treatment step, makes the developed method of great value for rapid screening analysis of a large number of amines. A very fast and efficient separation (<11min) of PAAs was achieved. Detection limits in the 0.06-0.7μgkg(-1) range were calculated for 17 out of 22 of the investigated PAAs, however obtaining values within 5.3μgkg(-1) for the other 5 amines. Good dynamic linear ranges from two to four orders of magnitude (r(2)≥0.990) were obtained and satisfying results were achieved in terms of intra-day (RSDs<10%) and inter-day repeatability (RSDs<17%). Trueness values in the 70±1-131±5% range proved reliability of the developed method for PAAs quantification also at very low concentration levels. Finally, the method was successfully applied to a range of different real plastic multilayer food packaging materials, noticing in all cases levels below the established limits of detection.

摘要

欧盟法规规定,塑料食品接触材料不得释放出芳香胺(PAA),因为芳香胺是有毒化合物,也是疑似人类致癌物。作为现有 PAA 测定方法(基于分光光度法或靶向液相色谱-串联质谱法(LC-MS/MS)方法)的有效替代方法,本研究设计并验证了一种基于 LC-Orbitrap 全扫描-高分辨质谱(HRMS)的方法,用于测定食品接触材料中 22 种 PAA 的迁移水平,从而利用准确质量测量的特异性。在迁移后直接将模拟物(3%(w/v)乙酸)注入 LC-MS 系统,无需任何预处理步骤,使得开发的方法非常适合快速筛选分析大量胺类物质。通过该方法可以实现 PAA 的快速和高效分离(<11min)。22 种 PAA 中有 17 种的检测限在 0.06-0.7μgkg(-1)范围内,但对于其余 5 种胺类物质,仅能获得 5.3μgkg(-1)以内的值。从两个到四个数量级(r(2)≥0.990)获得了良好的动态线性范围,并在日内(RSDs<10%)和日间重复性(RSDs<17%)方面获得了令人满意的结果。开发的方法用于非常低浓度水平的 PAA 定量时,其准确度值在 70±1-131±5%范围内,证明了方法的可靠性。最后,该方法成功应用于一系列不同的真实塑料多层食品包装材料,在所有情况下,均检测到低于规定检测限的水平。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验