Suppr超能文献

对6名曾遭受意外电离辐射的受害者进行回顾性剂量估计,并采用荧光原位杂交(FISH)技术。

Assessment of retrospective dose estimation, with fluorescence in situ hybridization (FISH), of six victims previously exposed to accidental ionizing radiation.

作者信息

Liu Qing-Jie, Lu Xue, Zhao Xiao-Tao, Feng Jiang-Bin, Lü Yu-Min, Jiang En-Hai, Zhang Shu-Lan, Chen De-Qing, Jia Ting-Zhen, Liang Li

机构信息

China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, PR China.

China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, PR China.

出版信息

Mutat Res Genet Toxicol Environ Mutagen. 2014 Jan 1;759:1-8. doi: 10.1016/j.mrgentox.2013.07.016. Epub 2013 Nov 16.

Abstract

The present study aims to evaluate the use of the fluorescence in situ hybridization (FISH) translocation assay for retrospective dose estimation of acute accidental exposure to radiation in the past. Reciprocal translocation analysis by FISH with three whole-chromosome probes was performed on normal peripheral blood samples. Samples were irradiated with 0-5Gy (60)Co γ-rays in vitro, and dose-effect curves were established. FISH-based translocation analyses for six accident victims were then performed, and biological doses were estimated retrospectively by comparison with the dose-effect curves. Reconstructed doses by FISH were compared with estimated doses obtained by analysis of di-centrics performed soon after exposure, or with dose estimates from tooth-enamel electron paramagnetic resonance (EPR) data obtained at the same time as the FISH analysis. Follow-up FISH analyses for an adolescent victim were performed. Results showed that dose-effect curves established in the present study follow a linear-quadratic model, regardless of the background translocation frequency. Estimated doses according to two dose-effect curves for all six victims were similar. FISH dose estimations of three adult victims exposed to accidental radiation less than a decade prior to analysis (3, 6, or 7 years ago) were consistent with those estimated with tooth-enamel EPR measurements or analyses of di-centrics. Estimated doses of two other adult victims exposed to radiation over a decade prior to analysis (16 or 33 years ago) were underestimated and two to three times lower than the values obtained from analysis of di-centrics or tooth-enamel EPR. Follow-up analyses of the adolescent victim showed that doses estimated by FISH analysis decrease rapidly over time. Therefore, the accuracy of dose estimates by FISH is acceptable only when analysis is performed less than 7 years after exposure. Measurements carried out more than a decade after exposure through FISH analysis resulted in underestimation of the biological doses compared with values obtained through analysis of di-centrics and tooth-enamel EPR.

摘要

本研究旨在评估荧光原位杂交(FISH)易位分析在回顾性估算过去急性意外辐射暴露剂量方面的应用。使用三种全染色体探针通过FISH进行相互易位分析,对正常外周血样本进行检测。样本在体外接受0 - 5Gy的(60)Coγ射线照射,建立剂量效应曲线。然后对六名事故受害者进行基于FISH的易位分析,并通过与剂量效应曲线比较来回顾性估算生物剂量。将FISH重建的剂量与暴露后不久通过双着丝粒分析获得的估算剂量,或与FISH分析同时获得的牙釉质电子顺磁共振(EPR)数据的剂量估算值进行比较。对一名青少年受害者进行了后续FISH分析。结果表明,本研究中建立的剂量效应曲线遵循线性二次模型,与背景易位频率无关。根据两条剂量效应曲线对所有六名受害者的估算剂量相似。对三名在分析前不到十年(3、6或7年前)意外受辐射的成年受害者进行的FISH剂量估算,与通过牙釉质EPR测量或双着丝粒分析估算的结果一致。另外两名在分析前十年以上(16或33年前)受辐射的成年受害者的估算剂量被低估,比通过双着丝粒分析或牙釉质EPR获得的值低两到三倍。对青少年受害者的后续分析表明,通过FISH分析估算的剂量随时间迅速下降。因此,只有在暴露后不到7年进行分析时,FISH剂量估算的准确性才是可接受的。与通过双着丝粒分析和牙釉质EPR获得的值相比,暴露十多年后通过FISH分析进行的测量导致生物剂量被低估。