Suppr超能文献

线扫描与点扫描双轴共焦显微镜性能比较。

Comparison of line-scanned and point-scanned dual-axis confocal microscope performance.

出版信息

Opt Lett. 2013 Dec 15;38(24):5280-3. doi: 10.1364/OL.38.005280.

Abstract

The point-scanned dual-axis confocal (PS-DAC) microscope has been shown to exhibit superior capability to reject out-of-focus and multiply scattered light in comparison to its conventional single-axis counterpart. However, the slow frame rate (typically <5 Hz) resulting from point-by-point data collection makes these systems vulnerable to motion artifacts. While video-rate point-scanned confocal microscopy is possible, a line-scanned dual-axis confocal (LS-DAC) microscope provides a simpler means of achieving high-speed imaging through line-by-line data collection, but sacrifices contrast due to loss of confocality along one dimension. Here we evaluate the performance trade-offs between an LS-DAC and PS-DAC microscope with identical spatial resolutions. Characterization experiments of the LS-DAC and PS-DAC microscopes with tissue phantoms, in reflectance mode, are shown to match results from Monte Carlo scattering simulations of the systems. Fluorescence images of mouse brain vasculature, obtained using resolution-matched LS-DAC and PS-DAC microscopes, demonstrate the comparable performance of LS-DAC and PS-DAC microscopy at shallow depths.

摘要

点扫描双轴共焦(PS-DAC)显微镜已被证明在拒绝离焦和多次散射光方面具有优于传统单轴共焦显微镜的能力。然而,由于逐点数据采集导致的低帧率(通常<5 Hz)使得这些系统容易受到运动伪影的影响。虽然视频帧率的点扫描共焦显微镜是可能的,但线扫描双轴共焦(LS-DAC)显微镜通过逐行数据采集提供了一种更简单的实现高速成像的方法,但由于一维共聚焦性的丧失而牺牲了对比度。在这里,我们评估了具有相同空间分辨率的 LS-DAC 和 PS-DAC 显微镜之间的性能权衡。对 LS-DAC 和 PS-DAC 显微镜在反射模式下进行组织体模的特性实验,结果与系统的蒙特卡罗散射模拟结果相匹配。使用分辨率匹配的 LS-DAC 和 PS-DAC 显微镜获得的小鼠脑血管荧光图像,证明了 LS-DAC 和 PS-DAC 显微镜在浅景深下的性能相当。

相似文献

引用本文的文献

5
Dual-axis confocal microscopy for point-of-care pathology.用于即时护理病理学的双轴共聚焦显微镜。
IEEE J Sel Top Quantum Electron. 2019 Jan-Feb;25(1). doi: 10.1109/JSTQE.2018.2854572. Epub 2018 Jul 25.
7

本文引用的文献

6
Confocal endomicroscopy: instrumentation and medical applications.共聚焦内镜:仪器和医学应用。
Ann Biomed Eng. 2012 Feb;40(2):378-97. doi: 10.1007/s10439-011-0426-y. Epub 2011 Oct 13.
8
Point-of-care pathology with miniature microscopes.即时床旁检验病理学与微型显微镜。
Anal Cell Pathol (Amst). 2011;34(3):81-98. doi: 10.3233/ACP-2011-011.