Miyakoshi Akio, Ozaki Hironori, Otsuka Mitsuya, Hayashi Atsushi
Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama 930-0194, Japan.
ISRN Ophthalmol. 2014 Feb 2;2014:562062. doi: 10.1155/2014/562062. eCollection 2014.
Purpose. To examine the graft-host interface during Descemet's stripping automated endothelial keratoplasty (DSAEK) surgery with optical coherence tomography (OCT). Design. Prospective, interventional case series. Patients and Methods. Eight patients who underwent a DSAEK were included. A handheld OCT was used intraoperatively to examine the presence of interface fluid between the host cornea and the graft. Results. In 3 patients, no interface fluid was detected between the host cornea and the graft after the graft was attached by air injection. In 4 patients, interface fluid was detected after the graft was attached by air injection. The remaining interface fluid was drained through corneal stab incisions. One patient required a second surgery because the first surgery failed due to persistence of the interface fluid. All patients showed a complete attachment of the graft at one month after the DSAEK surgery. Conclusion. A handheld OCT is useful to detect the interface fluid between the host cornea and the graft during a DSAEK.
目的。使用光学相干断层扫描(OCT)检查Descemet膜剥脱自动内皮角膜移植术(DSAEK)手术期间的植片-宿主界面。设计。前瞻性、介入性病例系列。患者与方法。纳入8例行DSAEK的患者。术中使用手持式OCT检查宿主角膜与植片之间界面液的存在情况。结果。3例患者在通过空气注入附着植片后,宿主角膜与植片之间未检测到界面液。4例患者在通过空气注入附着植片后检测到界面液。剩余的界面液通过角膜穿刺切口引流。1例患者因首次手术因界面液持续存在而失败,需要进行二次手术。所有患者在DSAEK手术后1个月时植片均完全附着。结论。手持式OCT在DSAEK手术期间检测宿主角膜与植片之间的界面液很有用。