Gordon C, Swan A, Dieppe P
University Department of Medicine, Bristol Royal Infirmary.
Ann Rheum Dis. 1989 Sep;48(9):737-42. doi: 10.1136/ard.48.9.737.
Polarised light microscopy of synovial fluid is an established diagnostic technique widely regarded as reliable for the detection of crystals. The threshold concentration of crystals which can be detected has been investigated and the sensitivity and specificity of six observers compared. Various concentrations of laboratory manufactured crystals of monosodium urate monohydrate (MSUM), calcium pyrophosphate dihydrate (CPPD), and basic calcium phosphates (BCP) were added to the synovial fluid. The threshold for reliable identification of MSUM and CPPD was in the range of 10-100 micrograms/ml. False positives were frequent. The mean sensitivity of the six observers for MSUM was 69% and for CPPD was 82%. The mean specificity for MSUM was 97% and for CPPD was 78%. There was much discrepancy in the results of the slides stained with alizarin red S. Thus the value of alizarin red S as a screening test for BCP is questioned. In view of the variable sensitivity and specificity of different observers for MSUM and CPPD and the concentration threshold for reliable crystal identification, greater caution in the interpretation of synovial fluid analysis is advised, and recommendations for increased quality control are supported.
滑膜液偏振光显微镜检查是一种公认的诊断技术,被广泛认为对晶体检测可靠。已对可检测到的晶体阈值浓度进行了研究,并比较了六位观察者的敏感性和特异性。将不同浓度的实验室制造的一水合尿酸钠(MSUM)、二水合焦磷酸钙(CPPD)和碱性磷酸钙(BCP)晶体添加到滑膜液中。可靠鉴定MSUM和CPPD的阈值在10 - 100微克/毫升范围内。假阳性很常见。六位观察者对MSUM的平均敏感性为69%,对CPPD的平均敏感性为82%。对MSUM的平均特异性为97%,对CPPD的平均特异性为78%。用茜素红S染色的玻片结果存在很大差异。因此,茜素红S作为BCP筛查试验的价值受到质疑。鉴于不同观察者对MSUM和CPPD的敏感性和特异性不同,以及可靠晶体鉴定的浓度阈值,建议在滑膜液分析的解读中更加谨慎,并支持加强质量控制的建议。