Suppr超能文献

与单纯乳腺钼靶摄影相比,双能对比增强减影乳腺钼靶摄影在致密型乳腺中的诊断性能:观察者间盲法读片分析。

Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

作者信息

Cheung Yun-Chung, Lin Yu-Ching, Wan Yung-Liang, Yeow Kee-Min, Huang Pei-Chin, Lo Yung-Feng, Tsai Hsiu-Pei, Ueng Shir-Hwa, Chang Chee-Jen

机构信息

Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkuo/TaoYuan, Taiwan,

出版信息

Eur Radiol. 2014 Oct;24(10):2394-403. doi: 10.1007/s00330-014-3271-1. Epub 2014 Jun 14.

Abstract

PURPOSE

To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx).

MATERIALS AND METHODS

CESM cases of dense breasts with histological proof were evaluated in the present study. Four radiologists with varying experience in mammography interpretation blindly read Mx first, followed by CESM. The diagnostic profiles, consistency and learning curve were analysed statistically.

RESULTS

One hundred lesions (28 benign and 72 breast malignancies) in 89 females were analysed. Use of CESM improved the cancer diagnosis by 21.2 % in sensitivity (71.5 % to 92.7 %), by 16.1 % in specificity (51.8 % to 67.9 %) and by 19.8 % in accuracy (65.9 % to 85.8 %) compared with Mx. The interobserver diagnostic consistency was markedly higher using CESM than using Mx alone (0.6235 vs. 0.3869 using the kappa ratio). The probability of a correct prediction was elevated from 80 % to 90 % after 75 consecutive case readings.

CONCLUSION

CESM provided additional information with consistent improvement of the cancer diagnosis in dense breasts compared to Mx alone. The prediction of the diagnosis could be improved by the interpretation of a significant number of cases in the presence of 6 % benign contrast enhancement in this study.

KEY POINTS

• DE-CESM improves the cancer diagnosis in dense breasts compared with mammography. • DE-CESM shows greater consistency than mammography alone by interobserver blind reading. • Diagnostic improvement of DE-CESM is independent of the mammographic reading experience.

摘要

目的

比较双能对比增强光谱乳腺摄影与对比增强减影乳腺摄影(CESM)及传统乳腺摄影(Mx)在致密型乳腺中诊断的准确性。

材料与方法

本研究评估了经组织学证实的致密型乳腺CESM病例。四位在乳腺摄影解读方面经验各异的放射科医生先对Mx进行盲法读片,随后对CESM进行读片。对诊断特征、一致性和学习曲线进行统计学分析。

结果

分析了89名女性的100个病灶(28个良性和72个乳腺恶性肿瘤)。与Mx相比,使用CESM使癌症诊断的敏感性提高了21.2%(从71.5%提高到92.7%),特异性提高了16.1%(从51.8%提高到67.9%),准确性提高了19.8%(从65.9%提高到85.8%)。使用CESM时观察者间的诊断一致性明显高于单独使用Mx(kappa比值分别为0.6235和0.3869)。在连续读片75例后,正确预测的概率从80%提高到了90%。

结论

与单独的Mx相比,CESM提供了额外信息,一致提高了致密型乳腺中癌症诊断的准确性。在本研究中,通过解读大量存在6%良性对比增强的病例,可提高诊断预测能力。

关键点

• 与乳腺摄影相比,双能对比增强光谱乳腺摄影(DE-CESM)提高了致密型乳腺中癌症诊断的准确性。• 通过观察者间盲法读片,DE-CESM显示出比单独乳腺摄影更高的一致性。• DE-CESM的诊断改善与乳腺摄影读片经验无关。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验