Bedirli Abdulkadir, Yucel Deniz, Ekim Burcu
Department of General Surgery, Gazi University Medical Faculty, Ankara, Turkey.
Gazi University Laparoscopic Surgery Education and Research Center, Ankara, Turkey.
JSLS. 2014 Jul-Sep;18(3). doi: 10.4293/JSLS.2014.00345.
Bowel anastomosis after anterior resection is one of the most difficult tasks to perform during laparoscopic colorectal surgery. This study aims to evaluate a new feasible and safe intracorporeal anastomosis technique after laparoscopic left-sided colon or rectum resection in a pig model.
The technique was evaluated in 5 pigs. The OrVil device (Covidien, Mansfield, Massachusetts) was inserted into the anus and advanced proximally to the rectum. A 0.5-cm incision was made in the sigmoid colon, and the 2 sutures attached to its delivery tube were cut. After the delivery tube was evacuated through the anus, the tip of the anvil was removed through the perforation. The sigmoid colon was transected just distal to the perforation with an endoscopic linear stapler. The rectosigmoid segment to be resected was removed through the anus with a grasper, and distal transection was performed. A 25-mm circular stapler was inserted and combined with the anvil, and end-to-side intracorporeal anastomosis was then performed.
We performed the technique in 5 pigs. Anastomosis required an average of 12 minutes. We observed that the proximal and distal donuts were completely removed in all pigs. No anastomotic air leakage was observed in any of the animals.
This study shows the efficacy and safety of intracorporeal anastomosis with the OrVil device after laparoscopic anterior resection.
前切除术之后的肠道吻合术是腹腔镜结直肠手术中最难完成的任务之一。本研究旨在评估一种在猪模型中,于腹腔镜下左侧结肠或直肠切除术后进行的新型可行且安全的体内吻合技术。
在5头猪身上对该技术进行评估。将OrVil装置(柯惠医疗公司,马萨诸塞州曼斯菲尔德)经肛门插入并向直肠近端推进。在乙状结肠做一个0.5厘米的切口,切断连接其输送管的两根缝线。在输送管经肛门抽出后,通过穿孔处移除钉砧尖端。用内镜直线切割吻合器在穿孔远端切断乙状结肠。用抓钳经肛门取出待切除的直肠乙状结肠段,并进行远端切断。插入一个25毫米的圆形吻合器并与钉砧结合,然后进行端侧体内吻合。
我们在5头猪身上实施了该技术。吻合平均需要12分钟。我们观察到所有猪的近端和远端切除圈均被完全取出。所有动物均未观察到吻合口漏气。
本研究表明腹腔镜前切除术后使用OrVil装置进行体内吻合的有效性和安全性。