Turner Thomas S, Tobin Daniel P, Delahunt Eamonn
1Leinster Rugby Branch, Irish Rugby Football Union, Dublin, Ireland; 2School of Public Health, Physiotherapy and Population Science, University College Dublin, Dublin, Ireland; and 3Institute for Sport and Health, University College Dublin, Ireland.
J Strength Cond Res. 2015 May;29(5):1234-9. doi: 10.1519/JSC.0000000000000770.
Recent research suggests that jump squats with a loaded hexagonal barbell are superior for peak power production to comparable loads in a traditional barbell loaded jump squat. The aim of this study was to investigate the relationship between relative peak power output during performance of the hexagonal barbell jump squat (HBJS), countermovement jump (CMJ) height, and linear acceleration speed in rugby union players. Seventeen professional rugby union players performed 10- and 20-m sprints, followed by a set of 3 unloaded CMJs and a set of 3 HBJS at a previously determined optimal load corresponding with peak power output. The relationship between HBJS relative peak power output, 10- and 20-m sprint time, and CMJ height was investigated using correlation analysis. The contribution of HBJS relative peak power output and CMJ height to 10- and 20-m sprint time was investigated using standard multiple regression. Strong, significant, inverse correlations were observed between HBJS relative peak power output, 10-m sprint time (r = -0.70, p < 0.01), and 20-m sprint time (r = -0.75, p < 0.01). A strong, significant, positive correlation was observed between HBJS relative peak power output and CMJ height (r = 0.80, p < 0.01). Together, HBJS relative peak power output and CMJ height explained 46% of the variance in 10-m sprint time while explaining 59% of the variance in 20-m sprint time. The findings of the current study demonstrate a significant relationship between relative peak power in the HBJS and athletic performance as quantified by CMJ height and 10- and 20-m sprint time.
最近的研究表明,使用六角杠铃进行负重深蹲跳在产生峰值功率方面优于传统杠铃负重深蹲跳中的同等负荷。本研究的目的是调查橄榄球联盟运动员在进行六角杠铃深蹲跳(HBJS)时的相对峰值功率输出、反向纵跳(CMJ)高度和线性加速速度之间的关系。17名职业橄榄球联盟运动员进行了10米和20米短跑,随后进行一组3次无负重CMJ和一组3次HBJS,负荷为先前确定的与峰值功率输出相对应的最佳负荷。使用相关分析研究了HBJS相对峰值功率输出、10米和20米短跑时间以及CMJ高度之间的关系。使用标准多元回归研究了HBJS相对峰值功率输出和CMJ高度对10米和20米短跑时间的贡献。观察到HBJS相对峰值功率输出与10米短跑时间(r = -0.70,p < 0.01)和20米短跑时间(r = -0.75,p < 0.01)之间存在强的、显著的负相关。观察到HBJS相对峰值功率输出与CMJ高度之间存在强的、显著的正相关(r = 0.80,p < 0.01)。HBJS相对峰值功率输出和CMJ高度共同解释了10米短跑时间方差的46%,同时解释了20米短跑时间方差的59%。本研究结果表明,HBJS中的相对峰值功率与通过CMJ高度以及10米和20米短跑时间量化的运动表现之间存在显著关系。