Suppr超能文献

种植体角度和印模技术对NobelActive种植体印模的影响。

Effect of implant angulation and impression technique on impressions of NobelActive implants.

作者信息

Alexander Hazboun Gillian Brewer, Masri Radi, Romberg Elaine, Kempler Joanna, Driscoll Carl F

机构信息

Former Resident, Advanced Specialty Education in Prosthodontics, Department of Endodontics, Prosthodontics, and Operative Dentistry, School of Dentistry, University of Maryland, Baltimore, Md.

Associate Professor, Department of Endodontics, Prosthodontics, and Operative Dentistry, School of Dentistry, University of Maryland, Baltimore, Md.

出版信息

J Prosthet Dent. 2015 May;113(5):425-31. doi: 10.1016/j.prosdent.2014.10.009. Epub 2015 Mar 4.

Abstract

STATEMENT OF PROBLEM

How the configuration of the NobelActive internal conical connection affects implant impressions is uncertain.

PURPOSE

The purpose of this study was to measure the effect in vitro of closed and open tray impression techniques for NobelActive implants placed at various angulations.

MATERIAL AND METHODS

Six NobelActive implants were placed in a master maxillary cast as follows: 0 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first molar area, 15 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first premolar area, and 30 degrees of angulation to a line drawn perpendicular to the occlusal plane in the lateral incisor area. Twelve open tray and 12 closed tray impressions were made. Occlusal, lateral, and frontal view photographs of the resulting casts were used to measure the linear and angular displacement of implant analogs. Statistical analysis was performed with a factorial analysis of variance (ANOVA), followed by the Tukey HSD test (α=.05).

RESULTS

No significant difference was found in the impressions made of NobelActive implants with the open or closed tray technique (linear displacement: F=0.93, P=.34; angular displacement: F=2.09, P=.15). In addition, implant angulation (0, 15, or 30 degrees) had no effect on the linear or angular displacement of impressions (linear displacement: F=2.72, P=.07; angular displacement: F=0.86, P=.43). Finally, no significant interaction was found between impression technique and implant angulation on NobelActive implants (F=0.25, P=.77; F=1.60, P=.20).

CONCLUSIONS

Within the limitations of this study, impression technique (open vs closed tray) and implant angulation (0, 15, and 30 degrees) had no significant effect on in vitro impressions of NobelActive implants.

摘要

问题陈述

NobelActive内部锥形连接的构型如何影响种植体印模尚不确定。

目的

本研究的目的是在体外测量采用闭口托盘和开口托盘印模技术对不同角度植入的NobelActive种植体的影响。

材料与方法

将6枚NobelActive种植体植入上颌主模型中,具体如下:在第一磨牙区域与垂直于咬合平面的直线呈0度角,在第一前磨牙区域与垂直于咬合平面的直线呈15度角,在侧切牙区域与垂直于咬合平面的直线呈30度角。制作了12个开口托盘印模和12个闭口托盘印模。对所得模型的咬合面、侧面和正面视图照片进行测量,以确定种植体代型的线性和角向位移。采用方差分析(ANOVA)进行统计分析,随后进行Tukey HSD检验(α = 0.05)。

结果

采用开口托盘或闭口托盘技术对NobelActive种植体进行印模时,未发现显著差异(线性位移:F = 0.93,P = 0.34;角向位移:F = 2.09,P = 0.15)。此外,种植体角度(0、15或30度)对印模的线性或角向位移没有影响(线性位移:F = 2.72,P = 0.07;角向位移:F = 0.86,P = 0.43)。最后,在NobelActive种植体上,印模技术与种植体角度之间未发现显著交互作用(F = 0.25,P = 0.77;F = 1.60,P = 0.20)。

结论

在本研究的局限性范围内,印模技术(开口托盘与闭口托盘)和种植体角度(0、15和30度)对NobelActive种植体的体外印模没有显著影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验