Suppr超能文献

在不同种植体角度下,通过不同印模技术获得的模型精度(体外研究)。

Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

作者信息

Elshenawy Enas A, Alam-Eldein Ahmed M, Abd Elfatah Fadel A

机构信息

Dental Biomaterials Department, Faculty of dentistry, Tanta University, Tanta, Egypt.

Prosthodontic Department, Faculty of dentistry, Tanta University, Tanta, Egypt.

出版信息

Int J Implant Dent. 2018 Mar 20;4(1):9. doi: 10.1186/s40729-018-0118-6.

Abstract

BACKGROUND

Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations.

METHODS

Three Osseolink implants were placed in three reference models with different angles (parallel, 15° and 30°). Impressions of each model were made with three techniques (n = 10 per group): indirect, unsplinted direct, and acrylic resin-splinted direct technique. Impressions were poured with type IV dental stone. Inter-implant distances were measured for casts using a coordinate measuring machine, and the deviations from the reference models (Δr) were calculated. Data were analyzed using one-way ANOVA followed by post hoc tests to detect significance between groups (α = 0.05).

RESULTS

This study showed that the deviations in micrometers from the reference model were the least for acrylic resin-splinted direct technique (Δr1 = 49.96, Δr2 = 50.36) versus indirect (Δr1 = 93.8, Δr2 = 90.9) and unsplinted direct techniques ((Δr1 = 67.07, Δr2 = 68.66) in 30° angulated implant situation (p value < 0.0001 for both Δr1 and Δr2). In 15° angulated implants, both the acrylic resin-splinted direct (Δr1 = 44.64, Δr2 = 45.58) and unsplinted direct techniques (Δr1 = 47.39, Δr2 = 55.28) were more accurate than indirect technique (Δr1 = 64.8, Δr2 = 68.3) (p value < 0.0001 for both Δr1 and Δr2). While in parallel condition, no difference was found between all three techniques (p value = 0.085, 0.056 for Δr1 and Δr2, respectively).

CONCLUSIONS

The impression technique affected the accuracy of definitive casts. The acrylic resin splinted direct technique produced the most accurate casts, followed by direct unsplinted and indirect techniques. Furthermore, implant angulation affected the impression accuracy. When implant angulation increased from parallel implants to 30°, the forces of deformation increased, which resulted in increased distortion.

摘要

背景

成角种植体可能导致印模不准确,并且印模技术可能会影响最终模型的准确性。本研究旨在比较三种印模技术在三种不同成角的下颌种植体最终模型上获得的模型的尺寸精度。

方法

将三个Osseolink种植体植入三个具有不同角度(平行、15°和30°)的参考模型中。每个模型采用三种技术制作印模(每组n = 10):间接法、无夹板直接法和丙烯酸树脂夹板直接法。用IV型牙科石膏灌注印模。使用坐标测量机测量模型的种植体间距离,并计算与参考模型的偏差(Δr)。使用单因素方差分析进行数据分析,随后进行事后检验以检测组间差异(α = 0.05)。

结果

本研究表明,在30°成角种植体情况下,与间接法(Δr1 = 93.8,Δr2 = 90.9)和无夹板直接法((Δr1 = 67.07,Δr2 = 68.66)相比,丙烯酸树脂夹板直接法从参考模型的微米偏差最小(Δr1 = 49.96,Δr2 = 50.36)(Δr1和Δr2的p值均<0.0001)。在15°成角种植体中,丙烯酸树脂夹板直接法(Δr1 = 44.64,Δr2 = 45.58)和无夹板直接法(Δr1 = 47.39,Δr2 = 55.28)均比间接法(Δr1 = 64.8,Δr2 = 68.3)更准确(Δr1和Δr2的p值均<0.0001)。而在平行情况下,三种技术之间未发现差异(Δr1和Δr2的p值分别为0.085、0.056)。

结论

印模技术影响最终模型的准确性。丙烯酸树脂夹板直接法制作的模型最准确,其次是直接无夹板法和间接法。此外,种植体角度影响印模准确性。当种植体角度从平行种植体增加到30°时,变形力增加,导致变形增加。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/213b/5859005/c4216626e9f8/40729_2018_118_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验