评估中风患者手部功能的简易测试的心理测量特性。

Psychometric properties of the simple test for evaluating hand function in patients with stroke.

作者信息

Shindo Keiichiro, Oba Hideki, Hara Joji, Ito Mari, Hotta Fujiko, Liu Meigen

机构信息

Department of Rehabilitation Medicine, Keio University School of Medicine , Tokyo , Japan .

出版信息

Brain Inj. 2015;29(6):772-6. doi: 10.3109/02699052.2015.1004740. Epub 2015 Mar 20.

Abstract

OBJECTIVE

The simple test for evaluating hand function (STEF) is widely used for clinical evaluation of upper extremity function in Japan. However, except for test-re-test reliability, its psychometric properties have not been investigated. The aim of this study is to explore its internal consistency, concurrent validity and responsiveness in patients with sub-acute stroke.

DESIGN

This was a prospective longitudinal study.

PATIENTS

Thirty-four inpatients who had suffered hemiparetic stroke within 60 days of participation were enrolled.

METHODS

To investigate its internal consistency and responsiveness, they were assessed with the STEF and Action Research Arm Test (ARAT) at admission and 3 weeks later. To explore its concurrent validity, the Fugl-Meyer Assessment (FMA), Motor Activity Log (MAL) and Functional Independence Measure (FIM™) were also evaluated at admission.

RESULTS

The Cronbach's alpha for the STEF was 0.98-0.99, indicating excellent internal consistency. The STEF score strongly correlated with the ARAT, FMA and MAL scores and moderately with the FIM™ score. Effect sizes and the standardized response mean were 0.27 and 0.52 for the STEF and 0.30 and 0.95 for the ARAT, respectively.

CONCLUSION

This study indicates that the STEF is reliable, valid and sensitive to changes when applied to patients with sub-acute stroke.

摘要

目的

用于评估手部功能的简易测试(STEF)在日本被广泛用于上肢功能的临床评估。然而,除了重测信度外,其心理测量特性尚未得到研究。本研究的目的是探讨其在亚急性卒中患者中的内部一致性、同时效度和反应性。

设计

这是一项前瞻性纵向研究。

患者

招募了34名在参与研究后60天内发生偏瘫性卒中的住院患者。

方法

为了研究其内部一致性和反应性,在入院时和3周后用STEF和动作研究臂测试(ARAT)对他们进行评估。为了探讨其同时效度,还在入院时评估了Fugl-Meyer评估(FMA)、运动活动日志(MAL)和功能独立性测量(FIM™)。

结果

STEF的Cronbach's alpha系数为0.98 - 0.99,表明具有出色的内部一致性。STEF评分与ARAT、FMA和MAL评分高度相关,与FIM™评分中度相关。STEF的效应量和标准化反应均值分别为0.27和0.52,ARAT为0.30和0.95。

结论

本研究表明,STEF应用于亚急性卒中患者时可靠、有效且对变化敏感。