Abstract

BACKGROUND

Wear debris of polyethylene has become a restraining factor of the durability for total hip arthroplasty (THA). Ceramic on ceramic (COC) has better wear resistance while the squeaking sound and prosthesis fracture are of concern. It is still a controversy that bearing couples are better for THA.

METHODS

We performed a systematic review of all English articles identified from PubMed (1966-), Embase (1980-) and the Cochrane Library. Clinical outcomes, complications, revision rates, and radiographic outcomes of COC-THA and ceramic on polyethylene (COP)-THA were compared and evaluated.

RESULTS

Eight prospective randomized trials enrolling a total of 1508 patients and 1702 THA surgeries were identified. Our results demonstrated the prosthesis fracture and the squeaking sound is significantly higher in COC group and higher wear rate of the COP. Hip function, loosening rate, dislocation rate, revision rate, and the osteolysis rate were comparable between two groups. According to Grading of Recommendations Assessment, Development and Evaluation system assessment, the strength of evidence was high for prosthesis fracture, dislocation, osteolysis, and moderate for radiolucent line or loosening, hip noise, and revision.

CONCLUSIONS

Up to now, there is insufficient evidence to identify any clinical advantage of COC compared with COP. Longer follow-up of larger randomized trial is needed to clarify the outcomes.

摘要

背景

聚乙烯磨损颗粒已成为全髋关节置换术(THA)耐久性的限制因素。陶瓷对陶瓷(COC)具有更好的耐磨性,但存在摩擦音和假体骨折等问题。对于THA哪种关节配对更好仍存在争议。

方法

我们对从PubMed(1966年起)、Embase(1980年起)和Cochrane图书馆检索到的所有英文文章进行了系统评价。比较并评估了COC-THA和陶瓷对聚乙烯(COP)-THA的临床结果、并发症、翻修率和影像学结果。

结果

共纳入8项前瞻性随机试验,涉及1508例患者和1702例THA手术。我们的结果表明,COC组的假体骨折和摩擦音发生率显著更高,COP的磨损率更高。两组之间的髋关节功能、松动率、脱位率、翻修率和骨溶解率相当。根据推荐分级评估、制定和评价系统评估,假体骨折、脱位、骨溶解的证据强度高,透亮线或松动、髋关节异响和翻修的证据强度中等。

结论

目前,尚无足够证据表明COC与COP相比具有任何临床优势。需要更大规模随机试验的更长时间随访来明确结果。