Kolarcik Christi L, Luebben Silvia D, Sapp Shawn A, Hanner Jenna, Snyder Noah, Kozai Takashi D Y, Chang Emily, Nabity James A, Nabity Shawn T, Lagenaur Carl F, Cui X Tracy
Department of Bioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA, USA.
Soft Matter. 2015 Jun 28;11(24):4847-61. doi: 10.1039/c5sm00174a. Epub 2015 May 20.
Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young's modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young's modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications.
目前用于与神经系统连接的微电极设计会引发一种特征性的炎症反应,导致瘢痕组织包裹,电极与组织电绝缘,最终失效。传统上,使用的是相对坚硬的材料,如钨和硅,它们的机械性能与神经组织相差几个数量级。这种机械不匹配被认为是装置周围慢性炎症和退变的主要原因。为了尽量减少神经接口装置与大脑之间的差异,制造了由弹性体和本征导电聚合物组成的新型软电极。对这些材料的物理、机械和电化学性能进行了广泛表征,以确定具有包括杨氏模量、断裂伸长率、极限拉伸强度、电导率、阻抗和表面电荷注入等参数最佳组合的配方。我们最终的电极杨氏模量为974 kPa,比钨低五个数量级,且明显低于其他基于聚合物的神经电极材料。体外细胞培养实验证明了这些软材料与神经元、星形胶质细胞和小胶质细胞之间的良好相互作用,与坚硬对照相比,软装置上神经元附着更高,炎症小胶质细胞附着减少了两倍。在这些微丝上表面固定神经元粘附蛋白进一步改善了细胞反应。最后,体内电生理学证明了弹性电极在记录啮齿动物视觉皮层单单位活动中的功能。所呈现的结果提供了支持在神经接口应用中使用软材料的初步证据。