Suppr超能文献

采用微创采血针技术采集并使用三种不同手持设备测定的奶牛毛细血管血中的葡萄糖浓度。

Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

作者信息

Mair B, Drillich M, Klein-Jöbstl D, Kanz P, Borchardt S, Meyer L, Schwendenwein I, Iwersen M

机构信息

Department for Farm Animals and Veterinary Public Health, Clinical Unit for Herd Health Management in Ruminants, University Clinic for Ruminants, University of Veterinary Medicine Vienna, 1210, Vienna, Austria.

FirstFarms Slovakia, 900 68, Plavecký Štvrtok, Slovakia.

出版信息

BMC Vet Res. 2016 Feb 24;12:34. doi: 10.1186/s12917-016-0662-3.

Abstract

BACKGROUND

Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard.

RESULTS

The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%).

CONCLUSIONS

The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations.

摘要

背景

奶牛在泌乳初期对葡萄糖有大量需求。对这一时期适应不良会导致能量负平衡过度,酮病风险增加,动物健康和生产受损。除了测量酮体,分析血液中的葡萄糖浓度被认为是诊断和鉴别酮病的有用手段。监测代谢参数需要多次采血。在其他物种中,已经引入了新的采血技术,即使用电子手持设备快速分析少量血液。本研究的目的是评估使用手持设备FreeStyle Precision(FSP,雅培公司)、GlucoMen LX Plus(GLX,美纳里尼公司)和WellionVet GLUCO CALEA(WGC,MED TRUST公司)测定奶牛毛细血管血中血糖的适用性。总共从干奶期和产奶期的荷斯坦 - 弗里生奶牛身上采集了240份毛细血管血样。使用采血针从外阴部皮肤采集血液。为了进行方法比较,还从尾静脉采集了额外的血样并在实验室进行分析。通过标准实验室方法测量的葡萄糖浓度被定义为标准对照。

结果

使用这些设备分析的毛细血管血中葡萄糖浓度与参考值之间的Pearson相关系数,FSP为73%,GLX为81%,WGC为41%。Bland - Altman图显示,FSP的偏差为 - 18.8 mg/dL,GLX为 - 11.2 mg/dL,WGC为 + 20.82 mg/dL。通过受试者工作特征分析确定的使用FSP检测高血糖的优化阈值为43 mg/dL,灵敏度(Se)和特异度(Sp)分别为76%和80%。使用GLX和WGC时,优化阈值分别为49 mg/dL(Se = 92%,Sp = 85%)和95 mg/dL(Se = 39%,Sp = 92%)。

结论

本研究结果表明,使用GLX检测奶牛毛细血管血中的高血糖具有良好的性能特征,使用FSP时性能中等。在本研究设置下,WGC不适合测定葡萄糖浓度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验