Suppr超能文献

尿碘:微板法与电感耦合等离子体质谱法测定尿碘的比较。

Urinary iodine: comparison of a simple method for its determination in microplates with measurement by inductively-coupled plasma mass spectrometry.

机构信息

Internal Medicine IV (Endocrinology, Diabetology, Angiology, Nephrology, and Clinical Chemistry), Eberhard-Karls-University, Tübingen, Germany.

Labor Dr. Limbach &Kollegen, GbR, Medizinisches Versorgungszentrum, Im Breitspiel 15, 69126 Heidelberg, Germany.

出版信息

Sci Rep. 2017 Jan 3;7:39835. doi: 10.1038/srep39835.

Abstract

The aim of our study was to develop and validate an inexpensive, rapid, easy to use quantitative method to determine urinary iodine without major procurement costs for equipment. The rationale behind introducing this method is the increasing demand for urinary iodine assessments. Our study included 103 patients (76 female, 27 male), age (arithmetic mean) 52 ± 17.3 years. Urinary iodine was determined in microplates by a modification of the Sandell-Kolthoff reaction. The results were compared with inductively-coupled plasma mass spectrometry (ICP-MS) for iodine, considered as reference method. Geometric mean of urinary iodine determined by the Sandell-Kolthoff reaction method was 62.69 μg/l (95% confidence interval 53.16-73.92) whereas by the ICP-MS method it was 65.53 μg/l (95% confidence interval 54.77-78.41). Passing-Bablok regression equations for both methods gave y = 3.374 + 0.873x (y: Sandell-Kolthoff method, x: ICP-MS). Spearman´s correlation coefficient was 0.981, indicating a very high degree of agreement between the two methods. Bland-Altman plots showed no significant systematic difference between the two methods. The modified Sandell-Kolthoff method using microtiter plate technique presented here is a simple, inexpensive semi-automated method to determine urinary iodine with very little toxic waste. Comparison with the ICP-MS-technique yielded a good agreement between the two methods.

摘要

本研究旨在开发和验证一种廉价、快速、易于使用的定量方法,无需大量设备采购成本即可测定尿碘。引入这种方法的依据是对尿碘评估的需求不断增加。本研究纳入了 103 名患者(76 名女性,27 名男性),年龄(算术平均值)为 52±17.3 岁。通过对 Sandell-Kolthoff 反应的改良,在微孔板中测定尿碘。将结果与电感耦合等离子体质谱法(ICP-MS)测定的碘进行比较,后者被视为参考方法。Sandell-Kolthoff 反应法测定的尿碘几何平均值为 62.69μg/l(95%置信区间 53.16-73.92),而 ICP-MS 法为 65.53μg/l(95%置信区间 54.77-78.41)。两种方法的 Passing-Bablok 回归方程分别为 y=3.374+0.873x(y:Sandell-Kolthoff 法,x:ICP-MS)。Spearman 相关系数为 0.981,表明两种方法之间具有非常高的一致性。Bland-Altman 图显示两种方法之间没有显著的系统差异。本研究使用微量滴定板技术对改良的 Sandell-Kolthoff 法进行了介绍,这是一种简单、廉价的半自动化方法,可用于测定尿碘,且产生的有毒废物很少。与 ICP-MS 技术的比较表明,两种方法之间具有良好的一致性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d2ed/5206638/10c55ce716b2/srep39835-f1.jpg