Abstract

OBJECTIVE

To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system.

METHODS

Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24-2 and 10-2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye.

RESULTS

There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24-2 right mean deviation (rs = -0.280, P = 0.049), 24-2 right visual field index (rs = -0.306, P = 0.030), 24-2 worse visual field index (rs = -0.304, P = 0.032), and 10-2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10-2 left mean deviation (rs = -0.294, P = 0.045) and 10-2 worse mean deviation (rs = -0.306, P = 0.037), respectively.

CONCLUSIONS

The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading.

摘要

目的

使用眼动追踪系统研究青光眼患者默读表现与视野缺损之间的关系。

方法

本研究纳入了50例青光眼患者(G组;平均年龄52.2岁,标准差:11.4岁)和20例正常对照者(N组;平均年龄46.9岁;标准差:17.2岁)。G组所有参与者均有早期至晚期青光眼性视野缺损,但双眼视力均优于20/20。参与者默读水平书写的日文文章,同时眼动追踪系统监测并计算每100个字符的阅读时长、每100个字符的注视次数以及平均注视时长,并将这些指标与右眼和左眼、较好眼和较差眼的Humphrey视野检测(24-2和10-2瑞典交互式阈值算法标准)的平均偏差和视野指数值进行比较。

结果

G组和N组在平均注视时长方面存在统计学显著差异(G组为233.4毫秒;N组为215.7毫秒;P = 0.010)。在G组内,观察到阅读时长与24-2右眼平均偏差(rs = -0.280,P = 0.049)、24-2右眼视野指数(rs = -0.306,P = 0.030)、24-2较差眼视野指数(rs = -0.304,P = 0.032)以及10-2较差眼平均偏差(rs = -0.326,P = 0.025)之间存在显著相关性。平均注视时长分别与10-2左眼平均偏差(rs = -0.294,P = 0.045)和10-2较差眼平均偏差(rs = -0.306,P = 0.037)之间存在显著相关性。

结论

视野缺损的严重程度可能会影响阅读表现的某些方面。至少就默读而言,较差眼的视野是阅读流畅性的一个重要因素。