Long Qin, Wang Jing-Yi, Xu Dong, Li Ying
Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
Department of Rheumatology and Clinical Immunology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
Int J Ophthalmol. 2017 May 18;10(5):711-716. doi: 10.18240/ijo.2017.05.08. eCollection 2017.
To compare the corneal biomechanics of Sjögren's syndrome (SS) and non-SS dry eyes with Corneal Visualization Scheimpflug Technology (CorVis ST).
Corneal biomechanics and tear film parameters, namely the Schirmer I test value, tear film break-up time (TBUT) and corneal staining score (CSS) were detected in 34 eyes of 34 dry eye patients with SS (SSDE group) and 34 dry eye subjects without SS (NSSDE group) using CorVis ST. The differences of the above parameters between the two groups were examined, and the relationship between corneal biomechanics and tear film parameters were observed.
The differences in age, sex, intraocular pressure (IOP) and central corneal thickness (CCT) were not significant between the two groups (>0.05). The tear film parameters had significant differences between the SSDE group and NSSDE group (all <0.05). Patients in the SSDE group had significantly lower A1-time and HC-time, but higher DA (=0.01, 0.02, and 0.02, respectively) compared with the NSSDE group. In the SSDE group, DA was negatively correlated with TBUT (=-0.38, =0.03); HC-time was negatively correlated with CSS (=-0.43, =0.02). In the NSSDE group, HC-time was again negatively correlated with CSS (=-0.39, =0.02).
There are differences in corneal biomechanical properties between SSDE and NSSDE. The cornea of SSDE tends to show less "stiffness", as seen by a significantly shorter A1-time and HC-time, but larger DA, compared with the cornea of NSSDE. Biomechanical parameters can be influenced by different tear film parameters in both groups.
采用角膜可视化Scheimpflug技术(CorVis ST)比较干燥综合征(SS)干眼患者与非SS干眼患者的角膜生物力学特性。
使用CorVis ST对34例SS干眼患者(SSDE组)的34只眼和34例非SS干眼受试者(NSSDE组)的34只眼进行角膜生物力学和泪膜参数检测,即泪液分泌试验I值、泪膜破裂时间(TBUT)和角膜染色评分(CSS)。比较两组上述参数的差异,并观察角膜生物力学与泪膜参数之间的关系。
两组患者的年龄、性别、眼压(IOP)和中央角膜厚度(CCT)差异无统计学意义(>0.05)。SSDE组和NSSDE组的泪膜参数差异有统计学意义(均<0.05)。与NSSDE组相比,SSDE组患者的A1时间和HC时间显著缩短,但DA值更高(分别为=0.01、0.02和0.02)。在SSDE组中,DA与TBUT呈负相关(=-0.38,=0.03);HC时间与CSS呈负相关(=-0.43,=0.02)。在NSSDE组中,HC时间再次与CSS呈负相关(=-0.39,=0.02)。
SSDE和NSSDE的角膜生物力学特性存在差异。与NSSDE的角膜相比,SSDE的角膜往往表现出较小的“硬度”,表现为A1时间和HC时间显著缩短,但DA值更大。两组患者的生物力学参数均可受不同泪膜参数的影响。