日本非糖尿病受试者中闪光葡萄糖监测系统的详细解读:葡萄糖负荷后血糖浓度的个体差异和差异[快速通讯]

Careful readings for a flash glucose monitoring system in nondiabetic Japanese subjects: individual differences and discrepancy in glucose concentrarion after glucose loading [Rapid Communication].

作者信息

Sekido Keiko, Sekido Takashi, Kaneko Atsuko, Hosokawa Manami, Sato Ai, Sato Yoshihiko, Yamazaki Masanori, Komatsu Mitsuhisa

机构信息

Department of Diabetes, Endocrinology and Metabolism, Division of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Japan.

Department of Drug Discovery Science, Shinshu University School of Medicine, Matsumoto, Japan.

出版信息

Endocr J. 2017 Aug 30;64(8):827-832. doi: 10.1507/endocrj.EJ17-0193. Epub 2017 Jul 25.

Abstract

The FreeStyle Libre Flash Glucose Monitoring System (FGM), which can continuously measure glucose concentration in the interstitial fluid glucose (FGM-ISFG), has been in clinical use worldwide. However, it is not clear how accurately FGM-ISFG reflects plasma glucose concentration (PG). In the present study, we examined the clinical utility of FGM by oral glucose tolerance test (OGTT). In eight healthy volunteers (3 males; mean age, 41.8 y) wearing FGM sensors for 14 days, OGTT was performed during days 1-7 and days 8-14, and then both FGM-ISFG and PG were compared. Parkes error grid analysis indicated that all of 65 FGM-ISFG values were within Zone A (no effect on clinical action) and Zone B (little or no effect on clinical outcome). However, in OGTT, the mean FGM-ISFG was higher than the mean actual PG at 30, 60, and 90 minutes after loading (155.5 vs. 139.2 mg/dL, 166.2 vs. 139.2 mg/dL, 149.5 vs. 138.2 mg/dL, respectively; p<0.05). Moreover, the area under the curve of FGM-ISFG was also significantly larger than that of PG (17,626.2 vs. 15,195.0 min·mg/dL; p<0.05). In four of eight subjects, FGM-ISFG tended to be higher than PG in both OGTTs, and the greatest difference between the two values was 58 mg/dL. FGM is useful for glycemic control, whereas it is not appropriate to change therapeutic regimens based on the judgment of nocturnal hypoglycemia and postprandial hyperglycemia by FGM-ISFG. Careful attention is required for proper application of FGM.

摘要

可连续测量组织间液葡萄糖(FGM-ISFG)中葡萄糖浓度的FreeStyle Libre Flash葡萄糖监测系统(FGM)已在全球临床应用。然而,尚不清楚FGM-ISFG反映血浆葡萄糖浓度(PG)的准确性如何。在本研究中,我们通过口服葡萄糖耐量试验(OGTT)检验了FGM的临床效用。在8名佩戴FGM传感器14天的健康志愿者(3名男性;平均年龄41.8岁)中,分别在第1 - 7天和第8 - 14天进行OGTT,然后比较FGM-ISFG和PG。帕克斯误差网格分析表明,65个FGM-ISFG值均在A区(对临床行动无影响)和B区(对临床结果影响很小或无影响)内。然而,在OGTT中,负荷后30、60和90分钟时,FGM-ISFG的平均值高于实际PG的平均值(分别为155.5对139.2mg/dL、166.2对139.2mg/dL、149.5对138.2mg/dL;p<0.05)。此外,FGM-ISFG的曲线下面积也显著大于PG(17,626.2对15,195.0min·mg/dL;p<0.05)。在8名受试者中的4名中,两次OGTT中FGM-ISFG均倾向于高于PG,两者间的最大差值为58mg/dL。FGM对血糖控制有用,然而,基于FGM-ISFG判断夜间低血糖和餐后高血糖来改变治疗方案并不合适。正确应用FGM需要谨慎关注。