Suppr超能文献

使用光学相干断层扫描血管造影术对小鼠视网膜灌注进行定量分析。

Quantitative analysis of retinal perfusion in mice using optical coherence tomography angiography.

作者信息

Alnawaiseh Maged, Brand Cristin, Bormann Eike, Wistuba Joachim, Eter Nicole, Heiduschka Peter

机构信息

Dept. of Ophthalmology, Germany.

Centre of Reproductive Medicine and Andrology, Germany.

出版信息

Exp Eye Res. 2017 Nov;164:151-156. doi: 10.1016/j.exer.2017.09.003. Epub 2017 Sep 7.

Abstract

PURPOSE

To evaluate repeatability of the quantitative analysis of vessel density in the retinas of healthy mice using optical coherence tomography angiography (OCT-A).

METHODS

Seventeen eyes of seventeen healthy mice aged 10-15 weeks (young) and 75-95 weeks (old) were included in this study. OCT-A was performed using RTVue XR Avanti (Optovue Inc., Fremont, California, USA) under general anaesthesia. The retina was imaged twice using a 3 × 3 mm scan. Retinal thickness and flow density data in the superficial and deep retinal OCT angiograms were extracted and analysed.

RESULTS

The differences between the flow density values (whole en face) in the first and second sessions were non-significant (superficial retinal OCT angiogram: first session: 45.4 ± 4.1% (39.1-55.3%); second session: 46.1 ± 4.7% (39.1-59.1%); p = 0.14; deep retinal OCT angiogram: first session: 47.1 ± 3.8% (39.4-53.4%); second session: 47.3 ± 3.7% (39.4-53.8%); p = 0.50). The repeatability assessment of retinal thickness yielded intraclass correlation coefficient (ICC) values ranging between (0.86-0.99) while the ICCs for the flow density measurements ranged from 0.87 to 0.92 for the superficial retinal OCT angiogram and 0.68 to 0.93 for the deep retinal OCT angiogram.

CONCLUSIONS

Repeated OCT-A measurement of mice retinal vessel density (VD) revealed valid repeatability, indicating that this non-invasive technology is sufficient for longitudinal assessment of vascular changes in various mouse models and thereby opening the way to in-depth, experimental analysis of the vascular aspects of different retinal diseases and monitoring of disease progression and the effects of treatments.

摘要

目的

使用光学相干断层扫描血管造影(OCT-A)评估健康小鼠视网膜血管密度定量分析的可重复性。

方法

本研究纳入了17只10 - 15周龄(年轻)和75 - 95周龄(年老)健康小鼠的17只眼睛。在全身麻醉下使用RTVue XR Avanti(美国加利福尼亚州弗里蒙特市Optovue公司)进行OCT-A检查。使用3×3毫米扫描对视网膜进行两次成像。提取并分析浅层和深层视网膜OCT血管造影中的视网膜厚度和血流密度数据。

结果

第一次和第二次检查中血流密度值(整个表面)的差异无统计学意义(浅层视网膜OCT血管造影:第一次检查:45.4±4.1%(39.1 - 55.3%);第二次检查:46.1±4.7%(39.1 - 59.1%);p = 0.14;深层视网膜OCT血管造影:第一次检查:47.1±3.8%(39.4 - 53.4%);第二次检查:47.3±3.7%(39.4 - 53.8%);p = 0.50)。视网膜厚度的可重复性评估得出组内相关系数(ICC)值在(0.86 - 0.99)之间,而浅层视网膜OCT血管造影血流密度测量的ICC值在0.87至0.92之间,深层视网膜OCT血管造影的ICC值在0.68至0.93之间。

结论

对小鼠视网膜血管密度(VD)进行重复的OCT-A测量显示出有效的可重复性,表明这种非侵入性技术足以对各种小鼠模型中的血管变化进行纵向评估,从而为深入实验分析不同视网膜疾病的血管方面以及监测疾病进展和治疗效果开辟了道路。