手持测力计和等速测力计在髋关节、膝关节和踝关节中的绝对可靠性及同时效度:系统评价与荟萃分析

Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis.

作者信息

Chamorro Claudio, Armijo-Olivo Susan, De la Fuente Carlos, Fuentes Javiera, Javier Chirosa Luis

机构信息

Carrera de Kinesiología, Escuela de Medicina, Edificio Ciencias de la Salud, Pontificia Universidad Católica de Chile, Av.Vicuña Mackenna 4860, Macul, Santiago, Phone number 56223541326, Chile.

Servicio Kinesiología, Clínica UC San Carlos de Apoquindo, Santiago, Chile.

出版信息

Open Med (Wars). 2017 Oct 17;12:359-375. doi: 10.1515/med-2017-0052. eCollection 2017.

Abstract

The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors.

摘要

本研究的目的是确定手持测力计(HHD)和等速测力计(ID)在下肢峰值扭矩评估中的绝对可靠性和同时效度。检索了Medline、Embase、CINAHL数据库中与肌肉测力的心理测量特性相关的研究。考虑测量标准误差SEM(%)或以平均值百分比表示的一致性界限LOA(%)的研究被视为确定绝对可靠性,而使用组内相关系数(ICC)的研究被视为确定测力计之间的同时效度。总共有17项研究纳入了荟萃分析。COSMIN检查表将它们评为中等至较差。使用HHD时,膝关节伸展的LOA(%)为33.59%,95%置信区间(CI)为23.91至43.26,踝关节跖屈的LOA(%)为48.87%,CI为35.19至62.56。使用ID时,髋关节内收和伸展;膝关节屈曲和伸展;以及踝关节背屈的LOA(%)低于15%。与HHD相比,使用ID获得的髋关节、膝关节和踝关节较低的LOA(%)。设备之间的ICC范围从踝关节背屈的0.62,CI(0.37至0.87)到髋关节内收的0.94,IC(0.91至0.98)。发现髋关节内收肌和髋关节屈肌的相关性非常高,膝关节屈肌/伸肌和踝关节跖屈/背屈肌的相关性为中等。