Abstract

PURPOSE

To compare the accuracy of four different intraocular lens (IOL) power calculation formulas for eyes with mean keratometry values greater than 46 diopters (D).

METHODS

Forty five eyes from 45 patients who were candidates for senile cataract surgery with mean keratometry values greater than 46 D were included. Calculation of the IOL power was performed by the Lenstar. The implanted IOL in all cases was Acrysof SA60AT. The average absolute value of the differences between the actual and predicted spherical equivalent (SE) of the postoperative refractive error (mean absolute error: MAE) was calculated using 4 formulas (Haigis, Holladay 1, Hoffer Q, and SRK/T) with optical IOL constants from the User Group for Laser Interference Biometry constants.

RESULTS

The MAE was smallest in the SRK/T formula (0.39 D ± 0.35) followed by those of the Holladay 1 (0.44 D ± 0.32), Haigis (0.45 D ± 0.35) and Hoffer Q (0.5 D ± 0.38) formulas. However, there was no statistically significant difference between the MAE among different formulas. The SRK/T formula predicted more eyes within ± 0.5 D of the SE (77.8%) compared to other formulas.

CONCLUSION

In eyes with steep corneas, there were no statistically significant differences among the accuracies of the four common IOL power calculation formulas.

摘要

目的

比较四种不同的人工晶状体(IOL)屈光力计算公式在平均角膜曲率值大于46屈光度(D)的眼中的准确性。

方法

纳入45例拟行老年性白内障手术且平均角膜曲率值大于46 D的患者的45只眼。IOL屈光力由Lenstar计算得出。所有病例植入的IOL均为Acrysof SA60AT。使用4种公式(Haigis、Holladay 1、Hoffer Q和SRK/T)并结合激光干涉生物测量用户组常数中的光学IOL常数,计算术后屈光不正实际与预测球镜等效度(SE)差值的平均绝对值(平均绝对误差:MAE)。

结果

SRK/T公式的MAE最小(0.39 D±0.35),其次是Holladay 1公式(0.44 D±0.32)、Haigis公式(0.45 D±0.35)和Hoffer Q公式(0.5 D±0.38)。然而,不同公式之间的MAE无统计学显著差异。与其他公式相比,SRK/T公式预测的SE在±0.5 D范围内的眼更多(77.8%)。

结论

在角膜陡峭的眼中,四种常见的IOL屈光力计算公式的准确性之间无统计学显著差异。

相似文献

引用本文的文献

本文引用的文献

7
Clinically relevant biometry.临床相关生物计量学。
Curr Opin Ophthalmol. 2012 Jan;23(1):47-53. doi: 10.1097/ICU.0b013e32834cd63e.
9
Improving the prediction accuracy of the SRK/T formula: the T2 formula.提高 SRK/T 公式的预测精度:T2 公式。
J Cataract Refract Surg. 2010 Nov;36(11):1829-34. doi: 10.1016/j.jcrs.2010.05.031.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验