Moore D G, Davis B G, Oefinger P E, Carlson J R
Am J Clin Pathol. 1985 May;83(5):622-5. doi: 10.1093/ajcp/83.5.622.
A total of 212 sera were assayed for antibody specific for cytomegalovirus by complement fixation (CF), indirect immunofluorescence (IFA Electro-Nucleonics Laboratory, Inc., Bethesda, MD), ELISA (Cordis Laboratories, Inc., Miami, FL) and the FIAX system (International Diagnostic Technology, Santa Clara, CA). Correlation of CF with IFA, ELISA, and FIAX was 61%, 78%, and 71%, respectively. Quantitative correlation between IFA and FIAX and ELISA was not possible because of the broad range of reaction intensity of the latter two tests in sera with a particular IFA titer.
采用补体结合试验(CF)、间接免疫荧光法(IFA,Electro-Nucleonics实验室,马里兰州贝塞斯达)、酶联免疫吸附测定(ELISA,Cordis实验室,佛罗里达州迈阿密)以及FIAX系统(国际诊断技术公司,加利福尼亚州圣克拉拉)对总共212份血清进行巨细胞病毒特异性抗体检测。CF与IFA、ELISA和FIAX的相关性分别为61%、78%和71%。由于后两项检测在具有特定IFA滴度的血清中的反应强度范围较宽,因此无法确定IFA与FIAX以及ELISA之间的定量相关性。